Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 2, Rev Date: 02/06/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
System Operation
The door is unlocked until the REX
timer has expired or until the door
has been opened and then closed.
AUTHORIZED EGRESS [REX] (Green LED Solid)
Door Closed
- -
- -
- -
- -
Door has been
opened
Keypad Code 22
*
The door is still locked and secure. The display is counting
down with audible alarm/voice instructions. Once the display
reaches “00”, the door will unlock.
15
14
01
DELAYED EGRESS MODE
RESET [Armed] (Green LED solid)
Keypad Code 11
*
The door is locked
and secure
15
30
or
-
-
POWER-UP LOCKED
The door is
locked and
secure
15
30
or
POWER-UP UNLOCKED
The door is unlocked. To enter the
Armed Mode, turn the keyswitch to
Reset or enter the Reset Code
“11 ” on the keypad
*
00
00
The door is unlocked and
has been opened
ALARMED UNLOCKED [Alternating Display]
- -
- -
- -
The door is unlocked and the alarm
is sounding. To return to Armed
Mode, close the door and turn the key
to Reset or enter the Reset Code “11 “
on the keypad
*
BYPASS [Extended Unlock] (Green LED Flashing)
Door Closed
- -
- -
- -
- -
Door has
been opened
Keypad Code 33
*
The door is unlocked indefinitely. To return to
Armed Mode, turn the keyswitch to Reset or
enter the Reset Code “11 “on the keypad.
*
KP
RST
C
NO
C
NO
C
NO
TRIG
REX
RESET
*
Returning the Keypad to Factory Default Settings
Short the
KP RST
terminal located on the main controller board.
Press 99# 1234 8# to enter programming mode and erase all users.
Press 3#1#2# . Sets the Output #1 (Reset) for 2 seconds.
Press 3#2#2# . Sets the Output #2 (Auth Exit) for 2 seconds.
Press 3#3#0# . Sets the Output #3 (Bypass) for latching.
Press 1#02#11#2# . Adds user # 2 with a code of 11 . [Reset]
Press 1#03#22#3# . Adds user # 3 with a code of 22 . [Auth Exit]
Press 1#04#33#4# . Adds user # 4 with a code of 33 . [Bypass]
Press to exit programming mode.
Remove the shorting jumper from the
KP RST
terminal.
*
*
*
*
*
*
*
**
*
*
*
Page 5 of 7