background image

Delayed Egress Wall Controller

Installation Instructions

I-EA00052

Rev 2, Rev Date: 02/06/15

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

System Operation

The door is unlocked until the REX

timer has expired or until the door

has been opened and then closed.

AUTHORIZED EGRESS [REX]   (Green LED Solid)

Door Closed

- -

- -

- -

- -

Door has been 

opened

Keypad Code 22

*

The door is still locked and secure.  The display is counting

down with audible alarm/voice instructions.  Once the display

reaches “00”, the door will unlock.

15

14

01

DELAYED EGRESS MODE

RESET  [Armed]   (Green LED solid)

Keypad Code 11

*

The door is locked

and secure

15

30

or

-

POWER-UP LOCKED

The door is

locked and 

secure

15

30

or

POWER-UP UNLOCKED

The door is unlocked.  To enter the

Armed Mode, turn the keyswitch to

             Reset or enter the Reset Code

“11   ” on the keypad

*

00

00

The door is unlocked and

has been opened

ALARMED UNLOCKED  [Alternating Display]

- -

- -

- -

The door is unlocked and the alarm

is sounding.  To return to Armed

Mode, close the door and turn the key

to Reset or enter the Reset Code “11   “

on the keypad

*

BYPASS  [Extended Unlock]    (Green LED Flashing)

Door Closed

- -

- -

- -

- -

Door has 

been opened

Keypad Code 33

*

The door is unlocked indefinitely.  To return to 

Armed Mode, turn the keyswitch to Reset or

enter the Reset Code “11   “on the keypad.

*

KP

RST

C

NO

C

NO

C

NO

TRIG

REX

RESET

*

Returning the Keypad to Factory Default Settings

Short the 

KP RST 

terminal  located on the main controller board.

Press 99# 1234   8#   to enter programming mode and erase all users. 

Press 3#1#2#   . Sets the Output #1 (Reset) for 2 seconds.

Press 3#2#2#   . Sets the Output #2 (Auth Exit) for 2 seconds.

Press 3#3#0#   . Sets the Output #3 (Bypass) for latching.

Press 1#02#11#2#   . Adds user # 2  with a code of 11   . [Reset]

Press 1#03#22#3#   . Adds user # 3  with a code of 22   . [Auth Exit]

Press 1#04#33#4#   . Adds user # 4  with a code of 33   . [Bypass]

Press       to exit programming mode.

Remove the shorting jumper from the  

KP RST

  terminal.  

*

*

*
*

*

*

*

**

*

*

*

Page 5 of 7

Содержание 2-679-0630

Страница 1: ...th security message or female voice with safety message Monitoring Outputs Armed mode Egress initiation status Released status Trigger Modes Egress alarm triggered by Push Bar Trigger input from external device field selectable N O or N C Code Compliance IFC International fire Code IBC International Building Code NFPA 101 Life Safety Code NFPA 1 Uniform Fire Code California Building Code Field sel...

Страница 2: ...screws supplied RECESSED DRY WALL MOUNTING KEY CYLINDER INSTALLATION WITH KEY CYLINDER IN PROPER POSITION INSIDE SWITCH BLOCK TIGHTEN THE SET SCREW TO LOCK CYLINDER IN PLACE 1 1 4 KEY CYLINDER REQUIRES COLLAR 3 3 4 1 Cut hole in dry wall to dimensions shown 2 Mount wall bracket over hole 3 Carefully insert unit and secure with screws supplied 5 3 4 PUSHUNTILALARM SOUNDS DOORCANBE OPENEDIN15SECONDS...

Страница 3: ...R COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 RECOMMENDED MOUNTING PROCEDURE WIRE UNIT AS SHOWN SHOWN WITH NO OPTIONS SLIDE PACKING FOAM BETWEEN WALL AND UNIT TO PREVENT DAMAGE TO FACEPLATE USE 1 1 4 SCREWS SUPPLIED WITH WALL MOUNT FRAME TO HANG UNIT TEMPORARILY FOR WIRING PURPOSES W H T W H T R E D B L K TO PANIC DEVICE FROM POWER SUPPLY Page 3 of 7 ...

Страница 4: ...15 20 30 1 N C N O UNLOCKED LOCKED VOICE TONE TONE ONLY FEMALE MSG MALE MSG ON DELAY TIME ON OFF 1 2 3 4 5 6 7 8 NUISANCE DELAY REX PERIOD TRIGGER TYPE PWR UP STATE ALARM TYPE MESSAGE JUMPER J1 PWR LOCK RED R NO C TRIG REX RESET C NO C NO C NO To Power Supply TANDEM UNIT PAIR OF DOORS WHT WHT BLK RED WHT WHT BLK RED POWER TRANSFER HINGE POWER TRANSFER HINGE DPS DPS To Power Supply PWR LOCK RED R N...

Страница 5: ...ypad 00 00 The door is unlocked and has been opened ALARMED UNLOCKED Alternating Display The door is unlocked and the alarm is sounding To return to Armed Mode close the door and turn the key to Reset or enter the Reset Code 11 on the keypad BYPASS Extended Unlock Green LED Flashing Door Closed Door has been opened Keypad Code 33 The door is unlocked indefinitely To return to Armed Mode turn the k...

Страница 6: ...t programming mode YELLOW Keypad is in Programming Mode For ADA requirements it will light each time a key is pressed Slow Flash Single Flash Adding a User Changing User Pin Codes Option 1 To add a user 1 Enter Programming Mode 2 Press 1 User Number 2 digits New Pin Code Output Code For example 99 1234 1 05 55 2 adds user 5 s pin code 55 as one that will activate authorized exit 3 Exit Programming...

Страница 7: ...gramming Steps 1 Test the controller to verify that all default codes are working as expected 2 Record all desired users names and PIN codes in the table below 3 Enter programming mode 4 Delete all default users using the Delete All Users option on page 6 5 Change the Master Code to the desired Master Code 6 Exit programming mode 7 Enter programming mode using the new Master Code to test it 8 Add ...