Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 2, Rev Date: 02/06/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display
·
Stop Employee Theft
·
Stop Retail Shoplifting
·
Restrict Airport Patrons
·
Restrict Wandering Patients
The integral verbal message, digital countdown display and sign
provide comprehensive and clear instructions of the door operation
for persons without prior knowledge of the exit delay, including the
sight and hearing impaired.
The digital keypad eliminates the need to carry and locate keys for
reset and bypass functions.
Features:
Egress Delay
·
15 or 30 second exit delay
·
1 or 2 second nuisance delay
Built-In 3 Function keypad
·
Alarm and lock reset
·
1 to 30 second bypass
·
Sustained bypass
·
Additional keyswitch optional
Control Inputs
·
1 to 30 second request-to-exit and
bypass input with anti-tailgate and
jumper selectable door prop alarm.
·
Reset
Built-In Annunciation
·
Armed mode
·
Nuisance mode
·
Irreversible egress mode
·
Release mode
·
Digital countdown mode
·
Field selectable voice notification or
tone
·
Field selectable male voice with
security message or female voice with
safety message
Monitoring Outputs
·
Armed mode
·
Egress initiation status
·
Released status
Trigger Modes
·
Egress alarm triggered by Push Bar
·
Trigger input from external device
field selectable (N/O or N/C)
Code Compliance
·
IFC International fire Code
·
IBC International Building Code
·
NFPA 101 Life Safety Code
·
NFPA 1 Uniform Fire Code
·
California Building Code
·
Field selectable automatic or manual power up after emergency release or power
loss. Use of manual power up complies with California Building Code (OSHPD)
requirements.
·
Choice of Mounting
·
Recessed mounted
(3 gang metal plaster ring included)
·
Surface mounted with optional 3
gang box (2-679-0641)
·
Optional shroud (2-679-0642) to be
used with (2-679-0641) surface box.
2-679-0630
WALL CONTROLLER
4500/4600
RIM MOUNT OR
VERTICAL ROD
EXIT DEVICES
NOTE: Hager 2908 Power Supply required
Application:
When unauthorized egress is initiated 4500 DE
delays egress through the door
for 15 seconds (or 30 seconds). Meanwhile,
the person exiting must wait while personnel
or security responds. The door unlocks after
15 seconds have elapsed permitting egress.
When powered by a fire control supervised
power supply, the lock will release
immediately in an emergency.
SYSTEM SPECIFICATIONS
INPUT VOLTAGE
INPUT VOLTAGE
MAX CURRENT DRAW
(SINGLE)
430mA @ 24 VDC
(TANDEM)
680mA @ 24 VDC
MONITOR RELAYS
CONTACT RATING
1 AMP @ 12/24 VDC
(RESISTIVE)
TEMPERATURE
o
0 C – 70 C
o