Operation
Preparation
- Apply power to the amplifier with connected sensors. Wait 15 minutes to warm up.
- Ensure that the completely mounted sensors are loaded with the normal pre-load acting in the regular
operating mode without any additional extraneous loads. In the case of Web tension sensors this is the
roll weight without any web (foil, paper, ...)
Adjustment mode
First press and hold the SET key to switch from the operating mode into the adjustment mode, afterwards
press the menu key
Ü
briefly and release the SET key.
The display indicates the 1. menu step which can now be changed.
For the second, third and any additional menu step do not press the SET key instead use the
menu key
Ü
to select the desired menu point, for instance, to make changes.
Storing of changes
Press the SET key until the LED goes OFF. This activates the adjustment procedure and the LED lights
up until the procedure is completed. The amplifier switches now automatically into the operating mode.
Leaving the adjustment mode without storage
When exceeding the waiting time of 20 seconds the amplifier switches without changes automatically into
the operating mode. An alternative is pressing the menu key beyond the 8. menu step.
Display intensity
(7. Menu step)
select the menu step "display intensity"
in the adjustment mode.
- select the display intensity of the LEDs
- all four LEDs blink during the adjustment
- store adjustment
Pre-Adjustments / Operating Modes
page 4
Filter type of the current output
(1. Menu step)
select the menu point "filter type"
in the adjustment mode
- select the operating mode
- LED blinks during the adjustment
- store adjustment
- if "FIL" was selected then the LED
remains ON in the operating mode
increasing
decreasing
HAEHNE
Elektronische Messgeräte GmbH · Heinrich-Hertz-Str. 29 · D-40699 Erkrath Germany · Telefon 0211/9 25 91-0 · Fax 0211/9 25 91-20
http://www.haehne.de
Email: [email protected]
HAEHNE