22
5.52.288.00.01.06
13.2
Periodic checks
Independently from the regulations of the individual countries, lifting devices must be checked at least yearly
by a qualified person or licensed qualified person regarding its functional safety.
13.3
Wire rope
Adequate performance of the servicing and monitoring work acc. to the validated, national regulations
“Basics for cable drives – monitoring during use”.
A visual check must be effected before every new work shift.
Wear
Deformation
Fissures
Corrosion
Report any damage immediately to the responsible person and exchange damaged or worn wire ropes and
load tackles.
13.4
Inspection intervals
on commissioning
daily checks
1st service after 3
months
inspection,
service every 3
months
inspection,
service every 12
months
Inspection of the equipment by a qualified person (periodic
inspection)
X
Check screw connections
X
X
Check brake function
X
X
check brake air gap (only for electric devices) *)
X
check overload protection if existent
X
clean and lubricate the wire rope
X
X
X
check wire rope and wire rope end fastenings for damage
and wear
X
check the load tackle and load hook for cracks and
deformation
X
*) not for EX design
Lubricate the toothed wheel of the drum
Winches from 250 kg up
X
14
Service
14.1
Wire rope
Wire ropes have to be exchanged by new, original wire ropes if they show corrosion, fracture or if they are
worn.
Checks:
Fastening screws must be checked before commissioning and at least every 3 months, - tighten them if
necessary.
Kind and number of broken threads.
Position of the broken threads
Timing sequence of occurrence of breaks.
Reduction of the wire rope diameter.
Corrosion
Abrasion
Deformation
Heat influence
Operation time
Wire rope fastening
CAUTION!
The wire rope must be replaced immediately should even one strand be broken.