Grounding and lightning protection 

The AP must be reliably grounded. Make sure the grounding points of the grounding conductor of 
the AP, lightning arresters, PE wire of the power cord, and antenna support are separate from each 
other, make good contact, and are securely connected and treated with corrosion protection. 

Ground resistance 

The ground resistance is typically  required to be less than 5 ohms, and less than  10 ohms in an 
area with less than 20 thunderstorm days a year. For a piece of angle steel buried in the earth as a 
grounding conductor, the ground resistance is required to be less than 10 ohms. In an area with a 
higher ground resistance, reduce the ground resistance by using brine or resistance reducing agent 
around the grounding conductor. 

The top of the grounding conductor must  be  a minimum of 0.7 m (2.30 ft) away from the  ground 
surface. In cold areas, the grounding conductor must be buried below the frozen soil layer. 

Grounding conductor 

If a grounding strip is available, connect the yellow and green grounding cable to the grounding strip. 
To make a grounding cable, make sure the cable has a cross-section area of a minimum of 6 mm

2

 

(0.01 in

2

) and a length of no longer than 3 m (9.84 ft). 

If no grounding strip is available, bury a piece of angle steel/steel tube a minimum of 0.5 m (1.64 ft) 
long in the earth to act as the grounding conductor. It must be zinc-plated. In the case of a piece of 
angle steel, the size must be a minimum of 50 × 50 × 5 mm (1.97 × 1.97 × 0.20 in). In the case of a 
piece of steel tube, it must  have a wall  thickness of a minimum of 3.5 mm (0.14 in).  Weld the 
grounding cable  of the AP onto the grounding conductor and use anti-erosion treatment on the 
welding joint. With a cross-section area of a minimum of 6 mm

2

 (0.01 in

2

), the grounding cable must 

be as short as possible and must not be coiled. 

Make sure the grounding terminals of all the lightning arresters of the AP and the peer device of the 
AP are reliably grounded. 

Ground lead 

A ground lead is a metal conductor connecting a grounding net and a  grounding strip. The 
grounding cable of the AP must be connected to the grounding strip. The ground lead must be 30 m 
(98.43 ft) or shorter. A piece of zinc-coated flat steel with a cross-section area of 40 × 4 mm (1.57 × 
0.16 in) or 50 × 5 mm (1.97 × 0.20 in) is recommended. Connect the grounding strip and the ground 
lead of the AP through the yellow and green grounding cable with an area of 35 mm

2

 (0.05 in

2

), or 

weld them directly. Use anti-erosion treatment on the welding joint. 

Power grounding (AC) 

Use a power cord with a protective earth (PE). Do not use a power cord with only an L line and an N 
line. 

Lightning rod 

The lightning protection grounding (for example, the grounding of the  lightning rod) must  be 
connected to the grounding conductor of the equipment room. 

The lightning rod must be tall enough to protect the AP and its antennas. 

In plain areas, the shielding angle of the lightning rod must be less than 45 degrees. In mountainous 
areas or lightning areas, the shielding angle must be less than 30 degrees. 

Ethernet cable 

Use a shielded twisted pair cable for outdoor installation. Make sure the devices at the two ends of 
the cable are reliably grounded. 

If a metal tube is used, make sure the Ethernet cable is reliably grounded at both ends of the tube. 

Содержание WA6630X

Страница 1: ...H3C WA6630X Access Point Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W102 20210126...

Страница 2: ...respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be acc...

Страница 3: ...ts that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...bles 2 5 Installing the AP 2 5 Pole mounting the AP by using the provided pole mounting kit 2 6 Pole mounting the AP by using the optional pole mounting kit 2 8 Pole mounting the AP by using band clam...

Страница 7: ...terference sources high power radars radio stations or electrical substations unstable voltage heavy vibration and loud noise The location is not water seeping water soaking and condensing The locatio...

Страница 8: ...hickness of a minimum of 3 5 mm 0 14 in Weld the grounding cable of the AP onto the grounding conductor and use anti erosion treatment on the welding joint With a cross section area of a minimum of 6...

Страница 9: ...lists the installation accessories to be prepared by users Figure 1 1 Installation accessories provided with the AP Figure 1 2 Installation accessories to be prepared by users Installation tools When...

Страница 10: ...1 4 Figure 1 3 Installation tools...

Страница 11: ...s have been treated with corrosion protection If you pole mount the AP on the top of a building make sure the AP does not project beyond the sides of the building To avoid high temperature caused by e...

Страница 12: ...rt Mount the AP on a custom pole Connect the AP to a power injector Label cables Verify the installation Power on the AP Troubleshoot the AP Power off the AP Operating correctly End Install the AP Pol...

Страница 13: ...the cable to the AP Connecting the grounding cable CAUTION Correctly connecting the grounding cable is crucial to lightning protection and EMI protection Before connecting the AP to the power source...

Страница 14: ...use the grounding screw to attach the ring terminal to grounding point on the AP Figure 2 5 Connecting the grounding cable to the AP Installing the protection cover Insert the protection cover into t...

Страница 15: ...VC pipes iron pipes Plica tube or cable troughs for cable routing Route cable pipes and troughs neatly against the wall and connect them through hoses or pipe joints at the bend Secure cable pipes and...

Страница 16: ...e sure the pole diameter is in the range of 50 to 75 mm 1 97 to 2 95 in Mounting the AP on a vertical pole 1 Secure the base of the pole to the rooftop or a concrete pier block by using expansion bolt...

Страница 17: ...the AP can rotate 4 Rotate and adjust the AP until the bubble in the level is in the middle 5 Fasten the two screws on the base to fix the rotation shaft of the AP Figure 2 10 Adjusting the AP Mountin...

Страница 18: ...and adjust the AP until the bubble in the level is in the middle 4 Fasten the two screws on the base to fix the rotation shaft of the AP Figure 2 12 Adjusting the AP Pole mounting the AP by using the...

Страница 19: ...the pole 2 Insert two hex screws into the installation holes at the top of the pole bracket Do not drive the screws all the way in leaving a certain space for hanging the AP Figure 2 14 Inserting hex...

Страница 20: ...5 As shown by callout 1 in Figure 2 16 use a T8 Torx screwdriver to loosen the two screws on the base so that the AP can rotate 6 Rotate and adjust the AP until the bubble in the level is in the middl...

Страница 21: ...ging the AP Figure 2 18 Inserting hex screws to the pole mounting brackets 3 Hang the AP on the pole mounting brackets by aligning the keyhole slots with the hex screws and then fasten the screws Figu...

Страница 22: ...mount the AP by using band clamps make sure the diameter of the band clamps is about 20 mm 0 79 in larger than that of the pole You can pole mount the AP by using stainless band clamps with a width of...

Страница 23: ...that the AP can rotate 4 Rotate and adjust the AP until the bubble in the level is in the middle 5 Fasten the two screws on the base to fix the rotation shaft of the AP Figure 2 22 Adjusting the AP Mo...

Страница 24: ...wdriver to loosen the two screws on the base so that the AP can rotate 4 Rotate and adjust the AP until the bubble in the level is in the middle 5 Fasten the two screws on the base to fix the rotation...

Страница 25: ...nstallation hole at the top of the pole mounting brackets Do not fasten the screws all the way in leaving a certain space for hanging the AP 3 Hang the AP on the pole mounting brackets by aligning the...

Страница 26: ...the middle 7 Fasten the two screws on the base to fix the rotation shaft of the AP Figure 2 28 Adjusting the AP Mounting the AP on a wall No expansion bolts are provided with the AP Prepare them your...

Страница 27: ...r hammer into each hole and then remove the nut and washers as shown in Figure 2 31 Keep the drill bit perpendicular to the wall and hold the drill handle tightly with both hands when drilling holes I...

Страница 28: ...33 use a T8 Torx screwdriver to loosen the two screws on the base so that the AP can rotate 5 Rotate and adjust the AP until the bubble in the level is in the middle 6 Fasten the two screws on the bas...

Страница 29: ...per uplink ports The PoE1 port on the dual port H3C power injector must be connected to the uplink network through the LAN1 port and PoE2 through LAN2 The following procedures use the PoE1 port as an...

Страница 30: ...oper places where they can be seen directly Use transparent waterproof tape to seal outdoor labels Verifying the installation CAUTION If the AP is used outdoors use the waterproof network cables dedic...

Страница 31: ...all command on the AC If the AP status is R M the AP has been connected to the network AC display wlan ap all Total number of APs 1 Total number of connected APs 1 Total number of connected manual AP...

Страница 32: ...ensions H W D 394 260 260 mm 15 51 10 24 10 24 in Weight 4 kg 8 82 lb System power consumption 10W 48 6W IEEE standards IEEE802 11a b g n ac ax IMPORTANT An AP with product code EWP WA6630X JP FIT can...

Страница 33: ...ding the image Blue Flashing at 1 Hz Only the 5G radio has associated clients Alternating between green and blue at 1 Hz Both the 2 4G and 5G radios have associated clients Ports The AP provides only...

Страница 34: ...1 0 1 in the MAP file and GigabitEthernet 1 for configuration on the AC GE2 PSE IEEE802 3 IEEE802 3i IEEE802 3u IEEE802 3ab Used for connecting the AP to an uplink device for Internet or MAN access It...

Отзывы: