2-1
2
Installing the device
WARNING!
Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open
the chassis, contact the local agent of H3C for permission. Otherwise, H3C shall not be liable for any
consequence caused thereby.
The installation procedure is similar for the H3C SecPath L5030, L5060, L5080 and L5000-E load
balancers. This section installs an L5000-E load balancer.
Installation flow
Table2-1 Installation flow for the device
Step
Description
1.
Start
Before installation, make sure all requirements on the checklist
are met and the device is powered off.
2.
Before installation, make sure the device and rack are reliably
grounded and you wear an ESD wrist strap.
Installing the device in a standard
19-inch rack
The device is heavy. Both mounting brackets and slide rails are
required to support the weight of the chassis.
4.
Before you install a power module, make sure the power
module is not connected to any power source and the grounding
cable of the device is connected reliably.
5.
Install compatible fan trays on the device.
6.
Installing an interface module
No MPU or interface module is provided with the device
Purchase them as required.
7.
Install compatible drives on the device.
8.
The device provides various ports. Choose compatible
transceiver modules and cables as required. To avoid bodily
injury or device damage, read the restrictions and guidelines
carefully before connection.
9.
Connect compatible power cords to the power modules.
10.
Verify that the device is installed securely and reliably
grounded, and that the power modules are as required.
Grounding the device
WARNING!
•
Correctly connecting the device grounding cable is crucial to lightning protection and EMI
protection. Before installing or using the devicel, connect the grounding cable to it correctly.
•
Do not connect the device grounding cable to a fire main or lightning rod.