2-5
The procedure is the same for connecting a grounding cable to the primary grounding point and the
auxiliary grounding point. This section uses the primary grounding point as an example.
To connect the grounding cable:
1.
Remove the grounding screw from the primary grounding point at the device rear.
2.
Attach the grounding screw to the ring terminal of the grounding cable.
3.
Use a screwdriver to fasten the grounding screw into the grounding hole.
4.
Connect the other end of the grounding cable to the grounding strip on the rack.
Figure2-5 Grounding the device at the primary grounding point
Installing a power module
CAUTION:
•
Before installing a power module, make sure the power module is not connected to any power
source and the grounding cable of the device is connected reliably.
•
Install a filler panel over an empty power module slot to prevent dust and ensure good ventilation
in the chassis.
•
Do not install both AC and DC power modules on the same device.
To install a power module:
1.
Face the rear panel of the device.
2.
Select the slot to install the power module.
3.
(Optional.) Remove the filler panel (if any) from the slot.
Figure2-6 Removing the filler panel
Auxiliary grounding point
Primary grounding point