34
Appendix B FRUs
The switch uses modular design.
describes the FRUs available for the switch.
Table 10 FRUs available for the switch
FRUs S6890-54HF
S6890-30HF
S6890-44HF
Power supplies
LSVM1AC650 Yes
Yes
No
LSVM1DC650 Yes
Yes
No
LSVM1AC300 No
Yes
No
LSVM1DC300 No
Yes
No
PSR450-12A1 No
No
Yes
PSR450-12A No
No
Yes
PSR450-12D No
No
Yes
PSR450-12AHD
No No Yes
Fan trays
LSWM1FANSA Yes
Yes
No
LSWM1FANSAB Yes
Yes
No
LSPM1FANSB No
No
Yes
LSPM1FANSA No
No
Yes
The switch can operate correctly with only one power supply. You can install two power supplies on
the switch for 1+1 redundancy.
To ensure heat dissipation, make sure all fan tray slots on the switch have fan trays installed and the
fan trays are the same model.
Power supplies
WARNING!
When the switch has power supplies in redundancy, you can replace a power supply without
powering off the switch. Make sure the power supply to be replaced is powered off before you
replace it.