30
Figure 39
Removing the power module
Connecting the power cord
CAUTION:
•
The AC power cord for the PSR150-A1 uses C13 connector, while the AC power cord for the
PSR360-56A/PSR720-56A/PSR1110-56A uses high-temperature C15 connector. Do not mix them.
•
Provide a circuit breaker for each power module and make sure the circuit breaker is off before
installation.
Table 5
Power cord connection procedures at a glance
Power module
Connection procedure reference
Fixed power module
AC input
Connecting an AC power cord to the switch
–48 VDC input
(External RPS power module:
RPS800-A or RPS1600-A)
Connecting a DC power cord to the switch
Hot swappable power module
PSR150-A1
PSR150-D1
(External RPS power module:
RPS800-A or RPS1600-A)
PSR360-56A
PSR720-56A
PSR1110-56A
Connecting the PSR360-56A/PSR720-56A/PSR1110-56A