background image

 

83 

 

NOTE: 

 

As a best practice, use H3C QSFP+ transceiver modules, QSFP+ cables, or QSFP+ to SFP+ cables for the 
QSFP+ ports on the switch. The H3C QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to SFP+ 
cables available for the QSFP+ ports are subject to change over time. For the most recent list of QSFP+ 

transceiver modules, QSFP+ cables, and QSFP+ to SFP+ cables available for the QSFP+ ports, contact 

H3C Support or marketing staff. 

 

You can use a QSFP-40G-SR4-MM850 or QSFP-40G-CSR4-MM850 transceiver module to connect a 
QSFP+ port to four SFP+ ports. The QSFP+ transceiver module and SFP+ transceiver modules to be 

connected must be the same in specifications, including central wavelength and fiber type. 

 

For more information about H3C QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to SFP+ cables, 

see 

H3C Transceiver Modules User Guide

 

Combo interface 

The S5560-30F-EI and S5560-34C-EI switches each provide eight combo interfaces. A combo interface 

contains an SFP port and a 10/100/1000BASE-T autosensing Ethernet port. Only one of these two ports 

can operate at a time. 

LEDs 

System status LED 

The system status LED shows the operating state of the switch.  

Table 29

 

System status LED description 

LED mark 

Status 

Description 

SYS 

Steady green 

The switch is operating correctly. 

Flashing green (1 Hz) 

The switch is performing power-on self test (POST). 

Steady red 

The switch has failed the POST or is faulty. 

Flashing yellow (1 Hz) 

Some ports have failed to pass POST or are faulty. 

Off 

The switch is powered off. 

 

Power module status LED 

The S5560-30C-EI, S5560-34C-EI, S5560-54C-EI, S5560-30F-EI, S5560-30C-PWR-EI, and 

S5560-54C-PWR-EI switches provide two power module slots at the rear. For each power module, these 

switches provide a power module status LED on the front panel.  

Table 30

 

Power module status LED description 

LED mark 

Status 

Description 

PWR1 Steady 

green 

A power module is installed in power module slot 1, and the 
power module is outputting power correctly. 

Содержание S5560-EI series

Страница 1: ...H3C S5560 EI Switch Series Installation Guide Hangzhou H3C Technologies Co Ltd http www h3c com Document version 6W102 20160822...

Страница 2: ...d All other trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice Every effort has bee...

Страница 3: ...s that you enter literally as shown Italic Italic text represents arguments that you replace with actual values Square brackets enclose syntax choices keywords or arguments that are optional x y Brace...

Страница 4: ...An alert that provides helpful information Network topology icons Represents a generic network device such as a router switch or firewall Represents a routing capable device such as a router or Layer...

Страница 5: ...ation guide Guides you through installing SFP SFP QSFP transceiver modules Pluggable modules manual Describes the hot swappable modules available for the H3C switches their external views and specific...

Страница 6: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 7: ...e AC power cord 22 Installing removing a fan tray 23 Installing a fan tray 23 Removing a fan tray 24 Installing removing a power module 25 Installing a PSR150 power module 26 Removing a PSR150 power m...

Страница 8: ...lay 55 Garbled display 55 Appendix A Chassis views and technical specifications 56 Chassis views 56 S5560 30S EI 56 S5560 54S EI 57 S5560 30F EI 58 S5560 30C EI 59 S5560 30C PWR EI 60 S5560 34C EI 61...

Страница 9: ...D 85 100 1000Base X SFP port LED 85 SFP port LED 86 QSFP port LED 86 Management Ethernet port LEDs 87 Expansion card status LED 87 Port status LED on the expansion card 88 Input status LED and output...

Страница 10: ...ace the switch on an unstable case or desk The switch might be severely damaged in case of a fall Ensure good ventilation of the equipment room and keep the air inlet and outlet vents of the switch fr...

Страница 11: ...tive humidity can cause washer contraction and ESD and cause problems including loose mounting screws and circuit failure High temperature can accelerate the aging of insulation materials and signific...

Страница 12: ...terference from the power grid Keep the switch far away from radio transmitting stations radar stations and high frequency devices Use electromagnetic shielding for example shielded interface cables w...

Страница 13: ...the switch CAUTION Keep the tamper proof seal on a mounting screw on the chassis cover intact and if you want to open the chassis contact H3C for permission Otherwise H3C shall not be liable for any...

Страница 14: ...rs Select and install power modules Hot swap power modules Yes No Operating correctly Turn off the circuit breakers Troubleshoot the switch No Yes Hot swap expansion cards Install expansion cards Yes...

Страница 15: ...595 mm 16 89 to 23 43 in orient the bracket with the wide flange inside the rack If the rack depth is in the range of 274 to 440 mm 10 79 to 17 32 in and the distance from the rear rack posts to the i...

Страница 16: ...the front rack post and the rear rack post must be in the range of 562 to 754 mm 22 13 to 29 69 in As a best practice use this method to rack mount a switch in data centers See Rack mounting by using...

Страница 17: ...EI S5560 54C PWR EI S5560 54QS EI Front mounting brackets Figure 5 Provided Provided Provided Rear mounting brackets and load bearing screws Figure 6 N A Provided Provided Chassis rails and slide rai...

Страница 18: ...d skin contact and is reliably grounded 3 Attach the front mounting brackets to the chassis a Unpack the front mounting brackets and the M4 screws supplied with the switch for attaching the brackets t...

Страница 19: ...taching the front mounting bracket to the power module side Figure 10 Attaching the front mounting bracket to the middle installation position 4 Mount the chassis in the rack a One person supports the...

Страница 20: ...11 Figure 11 Mounting the switch in the rack front mounting brackets at the port side Figure 12 Mounting the switch in the rack front mounting brackets at the power module side...

Страница 21: ...brackets 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Attach the front mounting brackets and load bearing screws to the chassis a Unpack the front mou...

Страница 22: ...5560 54QS EI 3 Attach the rear mounting brackets to the rack Orient the rear mounting brackets with the wide flange inside or outside the rack as required a Install cage nuts user supplied in the moun...

Страница 23: ...with the wide flange outside the rack 4 Mount the switch chassis in the rack a One person supports the chassis bottom with one hand holds the front part of the chassis with the other hand and pushes t...

Страница 24: ...with M6 screws user supplied to the front rack posts Make sure the front and rear mounting brackets have securely attached the switch to the rack Figure 18 Mounting the switch in the rack with the wid...

Страница 25: ...rews supplied with the switch to attach the mounting bracket to the chassis d Align one chassis rail with the screw holes in the chassis rail mounting position e Use M4 screws supplied with the switch...

Страница 26: ...and make sure they are at the same level as the slide rails d Supporting the bottom of the switch align the chassis rails with the slide rails on the rack posts as shown in Figure 22 Work with anothe...

Страница 27: ...18 Figure 22 Mounting the switch in the rack 1 Figure 23 Mounting the switch in the rack 2...

Страница 28: ...to the earth so the faradism and leakage electricity can be safely released to the earth to minimize EMI susceptibility of the switch You can ground the switch in one of the following ways depending...

Страница 29: ...the grounding cable to a length required for connecting to the grounding strip 3 Attach a ring terminal to the grounding cable a Use a wire stripper to strip 5 mm 0 20 in of insulation off the end of...

Страница 30: ...rt can securely attached to the grounding post on the grounding strip 3 Attach the bended part of the grounding cable to the grounding post and use the hex nut to fasten the bended part to the post Fi...

Страница 31: ...red switch through the PE wire of the power cord Make sure of the following information The power cord has a PE terminal The ground contact in the power outlet is securely connected to the ground in t...

Страница 32: ...ppable fan trays The switch comes with empty fan tray slots Choose the fan tray models based on the ventilation requirement of the site The air flow direction varies by fan tray model The LSPM1FANSA h...

Страница 33: ...e fan trays Do not place the fan tray in a moist place Prevent liquid from entering the fan tray Fan trays with faulty internal wiring and conductors require maintenance from maintenance engineers Do...

Страница 34: ...ce a power module without powering off the switch but you must strictly follow the installation and removal procedures in Figure 31 and Figure 32 to avoid any bodily injury or damage to the switch CAU...

Страница 35: ...se a flathead screwdriver to remove the filler panel Figure 33 Removing the filler panel 3 Unpack the power module and verify that the power module model is correct 4 Correctly orient the power module...

Страница 36: ...in the slot Installing a PSR360 56A PSR720 56A PSR1110 56A power module CAUTION To prevent damage to the power module or the connectors on the backplane insert the power module gently If you encounte...

Страница 37: ...ientation grasp the handle of the power module with one hand and support its bottom with the other and slide the power module slowly along the guide rails into the slot until you hear that the latch o...

Страница 38: ...atch towards the handle and pull the power module along the guide rails until it is part way out 4 Grasp the handle of the power module with one hand support the bottom with the other hand and pull th...

Страница 39: ...er is off before installation Table 5 Power cord connection procedures at a glance Power module Connection procedure reference Fixed power module AC input Connecting an AC power cord to the switch 48...

Страница 40: ...sides of the AC input power receptacle and pull the bail latch upwards see Figure 40 3 Connect one end of the AC power cord to the AC input power receptacle on the switch see callout 1 in Figure 41 4...

Страница 41: ...to push it in 3 Tighten the screws on the plug with a flat blade screwdriver to secure the plug in the power receptacle See callout 2 in Figure 42 4 Connect the two wires at the other end of the powe...

Страница 42: ...ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Unpack the DC power cord correctly orient the plug at one end of the cable with the power receptacle on the power mo...

Страница 43: ...or the PSR360 56A and PSR1 1 10 56A is similar To connect the PSR720 56A 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Plug the female connector end of...

Страница 44: ...EI S5560 30F EI S5560 54C EI S5560 30C PWR EI and S5560 54C PWR EI each have one expansion slot at the rear For the expansion cards available for the switches see Appendix B FRUs and compatibility mat...

Страница 45: ...Figure 48 c Rotate in the ejector lever as shown by callout 3 in Figure 48 d Use a Phillips screwdriver to tighten the captive screws on the expansion card to secure it in the slot See callout 4 in F...

Страница 46: ...37 Figure 48 Installing an expansion card with an ejector lever Figure 49 Installing an expansion card without an ejector lever...

Страница 47: ...f the expansion card has an ejector lever rotate out the ejector lever Skip this step if the expansion card does not have an ejector lever 4 Gently pull the expansion card out of the chassis along the...

Страница 48: ...provided with a serial console cable or Mini USB console cable Prepare these cables yourself or purchase them from H3C Figure 51 Connecting the console port to a PC Connecting the console cable A con...

Страница 49: ...le cable has a Mini USB Type B connector at one end to connect to the Mini USB console port of the switch and a standard USB Type A connector at the other end to connect to the USB port on the PC To c...

Страница 50: ...41 Figure 53 Device Driver Installation Wizard 6 Click Continue Anyway if the following dialog box appears Figure 54 Software Installation 7 Click Finish...

Страница 51: ...the terminal emulator programs see the user guides for these programs The following are the required terminal settings Bits per second 9 600 Data bits 8 Parity None Stop bits 1 Flow control None Power...

Страница 52: ...ions differ with software versions For more information about Boot ROM menu options see the software matching release notes for the device After the startup completes you can access the CLI to configu...

Страница 53: ...lity and manageability IRF fabric setup flowchart Figure 56 IRF fabric setup flowchart To set up an IRF fabric Step Description 1 Plan IRF fabric setup Plan the installation site and IRF fabric setup...

Страница 54: ...y of an IRF fabric equals the total switching capacities of all member switches Plan the installation site depending on your network solution as follows Place all IRF member switches in one rack for c...

Страница 55: ...o it When connecting two neighboring IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on the other switch As a best practice to a...

Страница 56: ...an SFP port is bound to an IRF port other SFP ports in the same port group cannot be used as service ports and vice versa Each QSFP port is a group For other models physical ports on different interfa...

Страница 57: ...ed IRF connection schemes and all these schemes use a ring topology IMPORTANT In these schemes all physical IRF ports are located on the same side If physical IRF ports are on different sides you must...

Страница 58: ...49 Figure 59 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...

Страница 59: ...master switch higher member priority than any other switch Bind physical ports to IRF port 1 on one switch and to IRF port 2 on the other switch You perform IRF port binding before or after connectin...

Страница 60: ...eb or SNMP to access the IRF fabric from the network management station See H3C S5560 EI Switch Series Fundamentals Configuration Guide 4 Verify that you can manage all member switches as if they were...

Страница 61: ...is normal but AC input has failed or AC input is not connected Off No RPS is connected AC input Symptom The system status LED is off Solution To resolve the problem a Verify that the AC power cord is...

Страница 62: ...ure can cause the power module to stop working and enter protection state f If the problem persists contact H3C Support Symptom 2 The system status LED is on but the RPS status LED is steady yellow So...

Страница 63: ...d If the problem persists contact H3C Support To replace a hot swappable power module see Installing removing a power module Fan failure Fixed fan failure The S5560 30S EI and S5560 54S EI switches u...

Страница 64: ...resolve the problem 1 Verify that the power module is supplying power to the switch 2 Verify that the console cable is correctly connected 3 Verify that the console cable does not have any problems an...

Страница 65: ...0 100 1000BASE T autosensing Ethernet port LED 3 SFP port 4 Console port CONSOLE 5 Mini USB console port 6 Port LED mode switching button 7 LED for the port LED mode MODE 8 USB port 9 System status LE...

Страница 66: ...net port LED 3 SFP port 4 Console port CONSOLE 5 Mini USB console port 6 Port LED mode switching button 7 LED for the port LED mode MODE 8 USB port 9 System status LED SYS 10 RPS status LED RPS 11 SFP...

Страница 67: ...2 installed with a filler panel You can install one or two power modules for the switch as required In this figure two PSR150 A1 AC power modules are installed in the power module slots For more infor...

Страница 68: ...th a filler panel You can install one or two power modules for the switch as required In this figure two PSR150 A1 AC power modules are installed in the power module slots For more information about i...

Страница 69: ...talled with a filler panel You can install one or two power modules for the switch as required In this figure two PSR720 56A AC power modules are installed in the power module slots For more informati...

Страница 70: ...h a filler panel You can install one or two power modules for the switch as required In this figure two PSR150 A1 AC power modules are installed in the power module slots For more information about in...

Страница 71: ...You can install one or two power modules for the switch as required In this figure two PSR150 A1 AC power modules are installed in the power module slots For more information about installing and remo...

Страница 72: ...talled with a filler panel You can install one or two power modules for the switch as required In this figure two PSR720 56A AC power modules are installed in the power module slots For more informati...

Страница 73: ...nstalled with a filler panel You can install one or two power modules for the switch as required In this figure two PSR150 A1 AC power modules are installed in the power module slots For more informat...

Страница 74: ...8 8 Each and its corresponding SFP port form a combo interface 24 Expansion slots N A N A 1 on the rear panel 1 on the rear panel Power module slots N A N A 2 on the rear panel 2 on the rear panel Fan...

Страница 75: ...compliance UL60950 1 EN60950 1 IEC60950 1 GB4943 Table 11 Technical specifications for non PoE switch models 2 Item S5560 34C EI S5560 54C EI S5560 54QS EI Dimensions H W D 43 6 440 360 mm 1 72 17 32...

Страница 76: ...DC input 70 W Dual AC inputs 59 W Dual DC inputs 59 W Single AC input 88 W Single DC input 85 W Dual AC inputs 77 W Dual DC inputs 75 W Maximum power consumption Single AC input 107 W Single DC input...

Страница 77: ...100 VAC to 240 VAC 50 Hz or 60 Hz Max voltage range 90 VAC to 264 VAC 47 Hz to 63 Hz PSR1 1 10 56A AC input Rated voltage range 1 15 VAC to 240 VAC 50 Hz or 60 Hz Max voltage range 102 5 VAC to 264 VA...

Страница 78: ...PSR720 56A 810 W 30 W 1560 W 30 W 1 PSR1110 56A and 1 PSR360 56A 810 W 30 W 1200 W 30 W 2 PSR720 56A 810 W 30 W 1200 W 30 W 1 PSR1110 56A 810 W 30 W 810 W 30 W 1 PSR720 56A and 1 PSR360 56A 810 W 30 W...

Страница 79: ...2P Not supported Supported Supported Not supported LSWM2SP2PM Not supported Supported Supported Not supported LSWM2SP8PM Not supported Supported Supported Not supported LSWM2XGT2PM Not supported Suppo...

Страница 80: ...fications Reference PSR150 A1 Rated input voltage range 100 VAC to 240 VAC 50 Hz or 60 Hz Max input voltage range 90 VAC to 264 VAC 47 Hz to 63 Hz Max output power 150 W H3C PSR150 A PSR150 D Series P...

Страница 81: ...n Trays User Guide LSPM1FANSB fan tray Dimensions 40 40 104 mm 1 57 1 57 4 09 in Fan speed 20000 R P M Max airflow 20 CFM Airflow direction Front to back from the network port side to the power module...

Страница 82: ...terface card Port type and quantity 2 1 10GBASE T Ethernet port Interface specifications See Table 21 Reference H3C LSWM2XGT2PM LSWM2XGT8PM Interface Cards User Manual LSPM4G4T6P Description 4 port 10...

Страница 83: ...umbered 5 through 8 on the interface card are not available 2 Ports GigabitEthernet 1 0 41 through GigabitEthernet 1 0 48 on the front panel are not available The operating modes supported by the inte...

Страница 84: ...in their first 20 m 65 62 ft Separate power cords and twisted pair cables at and around the distribution frame For ports adjacent to one another on the device the peer ports on the distribution frame...

Страница 85: ...C running terminal emulation program Management Ethernet port The S5560 30C EI S5560 34C EI S5560 30F EI S5560 54C EI S5560 30C PWR EI and S5560 54C PWR EI switches provide a management Ethernet port...

Страница 86: ...Specification Connector type RJ 45 Interface attributes 10 Mbps full duplex 100 Mbps full duplex 1000 Mbps full duplex MDI MDI X auto sensing Max transmission distance 100 m 328 08 ft Transmission med...

Страница 87: ...tches separate these transceiver modules by other types of transceiver modules For example you can install the SFP GE LH100 SM1550 transceiver modules in ports 1 and 2 other transceiver modules in por...

Страница 88: ...M13 10 A 1310 LC Single mode 9 125 N A 10 km 6 21 miles Multi mode 50 125 500 or 400 550 m 1804 46 ft Multi mode 62 5 125 500 550 m 1804 46 ft SFP GE LH40 S M1310 1310 LC Single mode 9 125 N A 40 km 2...

Страница 89: ...5 200 33 m 108 27 ft 160 26 m 85 30 ft SFP XG LX220 M M1310 1310 LC Multi mode 50 125 1500 220 m 721 78 ft 500 400 100 m 328 08 ft Multi mode 62 5 125 200 220 m 721 78 ft 160 SFP XG LX SM13 10 1310 LC...

Страница 90: ...ations of H3C SFP SFP transceiver modules and cables see H3C Transceiver Modules User Guide QSFP port The S5560 30S EI S5560 54S EI and S5560 54QS EI switches and the LSWM2QP2P interface card provide...

Страница 91: ...QSTK2 5 m 16 40 ft Table 28 QSFP to SFP cables available for the QSFP ports QSFP to SFP cable Max transmission distance LSWM1QSTK3 1 m 3 28 ft LSWM1QSTK4 3 m 9 84 ft LSWM1QSTK5 5 m 16 40 ft Figure 81...

Страница 92: ...tches each provide eight combo interfaces A combo interface contains an SFP port and a 10 100 1000BASE T autosensing Ethernet port Only one of these two ports can operate at a time LEDs System status...

Страница 93: ...e AC input are normal Steady yellow The RPS DC input is normal but the AC input is disconnected or has failed Off The RPS DC input is abnormal or no RPS is connected LED for the port LED mode MODE To...

Страница 94: ...E power supply is normal Flashing green 3 Hz The device attached to the port requires power higher than the maximum or currently available PoE output power on the port Steady yellow The port is experi...

Страница 95: ...k is present on the port and the port is operating at 1 Gbps Flashing yellow The port is sending or receiving data at 1 Gbps Flashing yellow 3 Hz The port has failed POST Off No link is present on the...

Страница 96: ...d one ACT LED for each management Ethernet port Table 38 Management Ethernet port LEDs description for the S5560 54QS EI switch LED mark Status Description LINK Off The management Ethernet port is not...

Страница 97: ...tput status LED on the power module The PSR360 56A PSR720 56A and PSR1 1 10 56A power modules each have an input status LED and an output status LED For more information about the LEDs see the manuals...

Страница 98: ...m the port side to the power module side for the switch by using different fan trays For heat dissipation install two fan trays of the same model for the switch Table 40 Cooling system for the S5560 E...

Страница 99: ...90 Figure 84 Airflow through the S5560 54C EI switch with air vents in the two sides Figure 85 Airflow through the S5560 54QS EI switch without air vents in the two sides...

Страница 100: ...tibility matrixes 70 70 configuring IRF basic settings 50 switch 39 troubleshooting configuration terminal problems 55 verify the IRF fabric setup 51 52 connecting AC power cord 31 console cable 39 DC...

Страница 101: ...entration 2 site gas saturation 2 site humidity 2 site temperature 2 examining installation site 1 F fan failure troubleshooting 54 fan tray installation 23 23 removal 23 24 status LED 88 technical sp...

Страница 102: ...orkbench switch mounting 19 hot swappable fan failure troubleshooting 54 hot swappable power module failure troubleshooting 53 humidity installation site 2 I ID IRF member 45 identifying IRF master sw...

Страница 103: ...t setting up IRF fabric 44 troubleshooting configuration terminal problems 55 networking planning IRF cabling scheme 47 no display troubleshooting 55 P parity parameter 42 PC troubleshooting garbled t...

Страница 104: ...rackets on 19 inch rack 12 rack mounting by using front mounting brackets and mounting rail assemblies on 19 inch rack 16 rack mounting by using front mounting brackets on 19 inch rack 9 removing PPSR...

Страница 105: ...identifying IRF member switch physical ports 47 installation 1 4 LEDs 76 planning IRF cabling scheme 47 47 planning IRF member IDs 45 ports 76 powering on 42 setting configuration environment 39 sett...

Страница 106: ...eme 47 47 topology IRF fabric 46 troubleshooting configuration terminal problems 55 fan failure 54 fixed fan failure 54 fixed power module failure 52 garbled display 55 hot swappable fan failure 54 ho...

Отзывы: