35
To do…
Use the command… Remarks
Configure the data
bits
databits
{
5 | 6 | 7
|
8
}
Optional
By default, the data bits of the console port is 8.
Data bits is the number of bits representing one
character. The setting depends on the contexts to
be transmitted. For example, you can set it to 7 if
standard ASCII characters are to be sent, and
set it to 8 if extended ASCII characters are to be
sent.
Define a shortcut
key for enabling a
terminal session
activation-key
character
Optional
By default, you can press
Enter
to enable a
terminal session.
Define a shortcut
key for terminating
tasks
escape-key
{
default
|
character }
Optional
By default, you can press
Ctrl+C
to terminate a
task.
Configure the flow
control mode
flow-control
{
hardware
|
none
|
software
}
Optional
By default, the value is
none
.
The switch supports the
none
flow control mode
only.
Configure the type
of terminal display
terminal type
{
ansi |
vt100
}
Optional
By default, the terminal display type is ANSI.
The device supports two types of terminal
display: ANSI and VT100. H3C recommends
you to set the display type of both the device and
the client to VT100. If the device and the client
use different display types (for example, hyper
terminal or Telnet terminal) or both are set to
ANSI, when the total number of characters of the
currently edited command line exceeds 80, an
anomaly such as cursor corruption or abnormal
display of the terminal display may occur on the
client.
Configure the user
privilege level for
login users
user privilege level
level
Optional
By default, the default command level is 3 for the
AUX user interface.
Set the maximum
number of lines to
be displayed on a
screen.
screen-length
screen-length
Optional
By default, a screen displays 24 lines.
A value of 0 disables the function.
Set the size of
history command
buffer
history-command
max-size
value
Optional
By default, the buffer saves 10 history
commands at most.