H3C S5110V2 Series Скачать руководство пользователя страница 2

Copyright © 2017-2019, New H3C Technologies Co., Ltd. and its licensors 

 

All rights reserved 

No part of this manual may be reproduced or transmitted in any form or by any means without prior written 
consent of New H3C Technologies Co., Ltd. 

Trademarks 

Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this 
document are the property of their respective owners. 

Notice 

The information in this document is subject to change without notice. All contents in this document, including 
statements, information, and recommendations, are believed to be accurate, but they are presented without 
warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions 
contained herein. 

Environmental protection 

This product has been designed to comply with the environmental protection requirements. The storage, use, 
and disposal of this product must meet the applicable national laws and regulations. 

 

Содержание S5110V2 Series

Страница 1: ...H3C S5110V2 Switch Series Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W102 20190128...

Страница 2: ...respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be acc...

Страница 3: ...ntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optio...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...terminal parameters 12 Starting the switch 12 Power on check 12 Starting the switch 12 Setting up an IRF fabric 14 IRF fabric setup flowchart 14 Planning IRF fabric setup 15 Planning IRF fabric size a...

Страница 7: ...ecifications 26 Appendix C Ports and LEDs 28 Ports 28 Console port 28 10 100 1000BASE T autosensing Ethernet port 28 SFP port 28 LEDs 30 System status LED 30 RPS status LED 31 Mode LED MODE 31 SFP por...

Страница 8: ...itch is just powered off To avoid ESD damage wear an ESD wrist strap to hot swap a power module Examining the installation site The S5110V2 switches must be used indoors You can mount your switch in a...

Страница 9: ...the equipment room Gas Maximum concentration mg m3 SO2 0 2 H2S 0 006 NH3 0 05 Cl2 0 01 EMI All electromagnetic interference EMI sources from outside or inside of the switch and application system adv...

Страница 10: ...apertures might hurt your eyes The S5110V2 switches are Class 1 laser devices Installation tools No installation tools are provided with the switch You might need the following installation tools Prep...

Страница 11: ...r any consequence Figure 1 Hardware installation flow Installing the switch in a 19 inch rack Mounting brackets The switch is provided with mounting brackets as shown in Figure 2 Start Install the swi...

Страница 12: ...chassis Figure 3 Attaching a mounting bracket S5110V2 52P switch Rack mounting the switch This task requires two people To mount the switch in the rack 1 Wear an ESD wrist strap and make sure it makes...

Страница 13: ...TION Correctly connecting the grounding cable is crucial to lightning protection and EMI protection To guarantee the grounding effect connect the switch to a grounding strip in the equipment room usin...

Страница 14: ...e rear panel of the switch b Attach the grounding screw to the ring terminal of the grounding cable c Use a screwdriver to fasten the grounding screw into the grounding screw hole Figure 5 Attaching t...

Страница 15: ...on must be a minimum of 50 50 5 mm 1 97 1 97 0 20 in The steel tube must be zinc coated and its wall thickness must be a minimum of 3 5 mm 0 14 in Weld the yellow green grounding cable to the angel ir...

Страница 16: ...nsert the female connector of the AC power cord into the AC input power receptacle on the switch See Figure 8 2 Use a cable tie to secure the p er cord to the cable tie holder near the AC power recept...

Страница 17: ...out 2 in Figure 10 3 Connect the other end of the power cord to an RPS Figure 10 Connecting the DC power cord S5110V2 52P PWR switch Verifying the installation After you complete the installation veri...

Страница 18: ...with a crimped RJ 45 connector at one end for connecting to the serial console port of the switch and a DB 9 female connector at the other end for connecting to the serial port on the configuration t...

Страница 19: ...tch verify that the following conditions are met The power cord is correctly connected The input power voltage meets the requirement of the switch The console cable is correctly connected The configur...

Страница 20: ...rmation about the configuration commands and CLI see H3C S5560S EI S5130S HI EI S5110V2 S3100V3 EI Switch Series Configuration Guides and H3C S5560S EI S5130S HI EI S5110V2 S3100V3 EI Switch Series Co...

Страница 21: ...eability IRF fabric setup flowchart Figure 13 IRF fabric setup flowchart To set up an IRF fabric Step Description 1 Plan IRF fabric setup Plan the installation site and IRF fabric setup parameters Pla...

Страница 22: ...ermine which switch you want to use as the master for managing all member switches in the IRF fabric An IRF fabric has only one master switch You configure and manage all member switches in the IRF fa...

Страница 23: ...an example For the ports that can be used for IRF connections see Table 5 Figure 14 IRF fabric in daisy chain topology Figure 15 IRF fabric in ring topology Identifying physical IRF ports on the memb...

Страница 24: ...RF ports on the switches 10 100 1000BASE T autosensing Ethernet ports Category 5 or above twisted pair cables SFP ports GE SFP transceiver modules and fibers or SFP cables For the available SFP transc...

Страница 25: ...guidelines when you configure the switches Assign the master switch higher member priority than any other switch Bind physical ports to IRF port 1 on one switch and to IRF port 2 on the other switch Y...

Страница 26: ...that you can manage all member switches as if they were one node 5 Display the running status of the IRF fabric by using the commands in Table 6 Table 6 Displaying and maintaining IRF configuration an...

Страница 27: ...e RPS is in position or working normally Steady yellow RPS power input is normal but AC input has failed or AC input is not connected Off No RPS is connected AC input failure Symptom The system status...

Страница 28: ...re of the switch is in the acceptable range and the power module has good ventilation Over temperature can cause the power module to stop working and enter the protection state 6 If the issue persists...

Страница 29: ...cable has been connected correctly 4 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None 5 Verify that the console c...

Страница 30: ...5110V2 28P Figure 19 Front panel 1 10 100 1000BASE T autosensing Ethernet port 2 10 100 1000BASE T autosensing Ethernet port LED 3 SFP port LED 4 System status LED SYS 5 Console port 6 SFP port Figure...

Страница 31: ...System status LED SYS 6 SFP port Figure 22 Rear panel 1 Grounding screw 2 AC input power receptacle S5110V2 28P HPWR Figure 23 Front panel 1 10 100 1000BASE T autosensing Ethernet port 2 Port LED mode...

Страница 32: ...anel 1 10 100 1000BASE T autosensing Ethernet port 2 10 100 1000BASE T autosensing Ethernet port LED 3 Console port 4 Port LED mode switching button 5 System status LED SYS 6 RPS status LED RPS 7 Mode...

Страница 33: ...UL60950 1 EN60950 1 IEC60950 1 GB4943 Melting current of power module fuse 2 A 250 V 3 15 A 250 V Cooling system Natural cooling without fan trays Using fixed fan trays to draw ambient air in from the...

Страница 34: ...al PoE power AC 370 W DC 740 W AC 370 W DC 740 W Minimum power consumption AC 19 W DC 11 W AC 36 W DC 26 W Maximum power consumption including PoE power consumption AC 448 W DC 782 W AC 467 W DC 807 W...

Страница 35: ...BASE T autosensing Ethernet port specifications Item Specification Connector type RJ 45 Interface attributes 10 Mbps half full duplex 100 Mbps half full duplex 1000 Mbps full duplex MDI MDI X autosens...

Страница 36: ...ft 160 200 m 656 17 ft SFP GE SX MM850 D 850 nm LC 50 125 m multi mode optical fiber 500 550 m 1804 46 ft 400 500 m 1640 42 ft 62 5 125 m multi mode optical fiber 200 275 m 902 23 ft 160 220 m 721 78...

Страница 37: ...ice use H3C transceiver modules and cables for the SFP ports The H3C transceiver modules and cables available for the SFP ports are subject to change over time For the most up to date list of H3C tran...

Страница 38: ...eady green The 10 100 1000BASE T autosensing Ethernet port LEDs are showing link state of the ports Flashing green The 10 100 1000BASE T autosensing Ethernet port LEDs are showing the PoE status of th...

Страница 39: ...t fails to meet the power requirement of the PD PoE power supply overcurrent overvoltage or short circuit occurs The remaining power of the switch fails to meet the power supply requirement of the por...

Страница 40: ...in a ToR solution 18 IRF member switches in one rack 17 IRF physical ports 18 planning IRF connections 15 power cord 8 console connecting cable 11 port technical specifications 28 D data bits paramet...

Страница 41: ...us LED 30 verifying switch 19 inch rack installation 10 workbench switch mounting 6 humidity installation site 1 I ID IRF member 15 identifying IRF master switch 15 IRF member switch physical ports 16...

Страница 42: ...grounding the switch 6 identifying IRF master switch 15 identifying IRF member switch physical ports 16 installing switch 4 installing switch on 19 inch rack 4 maintaining the switch 20 mounting switc...

Страница 43: ...ation terminal issues 22 troubleshooting power failure for switch with fixed power modules 20 system status LED 30 T technical specifications 26 10 100 1000 Base T autosensing Ethernet port LED 31 10...

Отзывы: