72
C
HAPTER
7: T
ROUBLESHOOTING
Stop bit: 1
Parity: None
Flow control: None
Terminal emulation: VT100
Reconfigure the parameters if their values are different.
Troubleshooting
Application Software
Upgrade
Symptom 1:
When upgrading the software using TFTP, the system displays:
boot device
: motfcc
unit number
: 1
processor number
: 0
file name
: main.bin
inet on ethernet (e) : 192.168.0.2
host inet (h)
: 192.168.0.1
user (u)
: guest
ftp password (pw)
: 123456
flags (f)
: 0x80
Loading...
Done!
0 bytes downloaded.
Something wrong with the file.
Solution:
Fault occurs because the source file does not exist, the network cable is not
connected, or the IP address of the PC is incorrect. Make sure that the source file is
in the TFTP root directory, the cable is connected securely, and the IP address is set
correctly.
Symptom 2:
When upgrading the software using TFTP, the system displays:
boot device
: motfcc
unit number
: 1
processor number
: 0
file name
: main.bin
inet on ethernet (e) : 192.168.0.2
host inet (h)
: 192.168.0.1
user (u)
: guest
ftp password (pw)
: 123456
flags (f)
: 0x80
Loading...
Done!
11487495 bytes downloaded.
Something wrong with the file.