Installation Manual
H3C SecPath F1000-A Firewall
Chapter 3 Hardware Installation
3-8
Caution:
Laser danger: never look into the optical ports that are connected to the laser. It can
harm your eyes.
Step 1: Correctly connect one end of a fiber-optic cable to the Rx port of the
10/100/1000 Mbps interface on the firewall and the other end to the Tx port on the peer
device. Connect another fiber-optic cable between the Tx port on the firewall and the
Rx port on the peer device.
Step 2: Power up the firewall and check the status of the LINK LED of the Ethernet 1
interface. On means the Rx link is present. OFF means no Rx link is present; check the
line for the cause.
3.7 Connecting a PSU
The H3C SecPath Series Firewall can be AC-powered or DC-powered. Except for PSU,
the two models are exactly the same with respect to functionalities and other features.
Note:
If both PSUs are connected, they operate in mutual backup mode.
3.7.1 Connecting an AC-Input PSU
I. AC-input PSU
AC input: 100 VAC to 240 VAC, 50 Hz or 60 Hz
Figure 3-6 illustrates the power socket on an AC-powered firewall: