7-4
CR-HIC-XP10
√
√
√
√
CR-HIC-GP12
×
√
√
√
CR-HIC-PU02
×
√
√
√
CR-HIC-PS04
×
√
√
√
CR-HIC-PHP08
×
√
√
√
CR-HIC-CLP04
×
√
√
√
CR-HIC-ET16
×
√
√
√
NOTE:
•
The mark
√ indicates that the interface subcard is compatible with the interface module.
•
The mark × indicates the interface subcard is not compatible with the interface module.
Fabric modules
describes the fabric modules available for the router.
Table7-4 Fabric modules available for the router
Fabric module model
Quantity for each chassis
CR-19K-SFU-16C
2 to 6
Fabric module filler panels
The router comes with empty fabric module slots. For good ventilation, purchase and install filler
panels in the empty fabric module slots.
Table7-5 Fabric module filler panels
Fabric module filler panel
Quantity for each chassis
CR19000-16 SFU filler panel
0 to 4
Power supplies
The PSR2400-54D, PSR2400-54A, and PSR3000-54A power supplies are available for the router.
The PSR2400-54D is a DC input and DC output power supply. The PSR2400-54A is an AC input and
DC output power supply. They provide a maximum output power of 2400 W.
The PSR3000-54A is an AC input and DC output power supply. It provides a maximum output power
of 3000 W.
The router supports N+M (single DC power input source) or N+N (dual AC power input sources)
power supply redundancy. Determine the number of power supplies based on the power input mode
and system power consumption. Make sure the maximum total output power of the power supplies is
greater than the system power consumption. Reserve a 20% power surplus as a best practice.