8-21
•
Three pairs of RUN and ALM LEDs
—Indicate the operating status of the fabric modules
covered by the fan tray (one pair of LEDs for each fabric module).
FAN-120B-6-A
Figure8-33 FAN-120B-6-A fan tray LEDs
(1) Fan tray status LEDs (OK and FAIL)
(2) Fabric module LEDs (RUN and ALM pairs)
Table8-33 FAN-120B-6-A fan tray LED description
LED
Status
Description
OK
Off
The fan tray is faulty.
Steady green
The fan tray is in normal state.
FAIL
Off
The fan tray is operating correctly.
Steady red
The fan tray is faulty.
RUN
Slow flashing green (0.5 Hz)
The fabric module is operating correctly.
Fast flashing green (4 Hz)
The fabric module is loading software.
CAUTION:
To avoid damaging the fabric module, do not power off the
router or hot swap the fabric module when the fabric module
is loading software.
Off
The fabric module is faulty or no fabric module is present.
ALM
Off
No alarm has occurred on the fabric module, or no fabric
module is present.
Steady red
An alarm has occurred on the fabric module.
Содержание CR19000-16
Страница 27: ...2 6 Figure2 6 Grounding the router ...
Страница 138: ...11 5 Figure11 6 Routing power cords ...
Страница 146: ...12 7 Figure12 5 Closing the carton ...