Page 4
To configure a manifold is a two step process. You must first set the pump type and then enter the chemical capacity per
stroke. Each output must be selected and configured separately.
1) Press
Enter
to choose the output number to configure.
2) Follow the screen instructions to set the pump type and Press
Enter
to set and display the Capacity per Stroke.
3) Press
Enter
again to set the stroke capacity using the numeric keypad. You must enter the decimal place, even
if zero. This capacity should be the total combined capacity of all pumpers attached to that output which are pumping
a single chemical and for which you want to display the combined feed ratio when setting the VPS.
4) After setting the values you will be returned to the Output selection screen where you can configure another output.
J Plus Advanced Start-Up Guide
HIGH FLOWS: 1 34
The “
HIGH FLOWS
” line is shown only when the flow exceeds the Max. Flow shown in line 2. The “
Max. Flow
” is the
computed flow at which the fastest (lowest VPS value) stroking manifold or Solenoid pump reaches its maximum stroking
rate. Each output has its own maximum flow, determined by its VPS setting. The lowest of these values is displayed on line
2. The output number of each output which exceeds its computed maximum is displayed on line 4. In the display above
outputs 1, 3, & 4 are affected. These outputs are being limited to their maximum stroking rate and therefore are pumping
less than their expected (set) feed rate.
MANIFOLDS UNDEFINED!
The message “
MANIFOLDS UNDEFINED!
” Is displayed when no manifolds are activated to pump. This occurs if no
outputs are turned or if the outputs which are turned on have a VPS setting of zero. Check the VPS settings (See
Setting
The VPS (Flow Volume per Stroke)
, Page 2) of all attached manifolds and make sure all the manifolds you want to pump
are turned on. This message is not affected by flow.
The totalizer displayed here
is the resettable total.
Warning & Information Messages (Display Line 4)
Setting the Pump Type and Stroke Capacity for Each Output
Enter
Set Value
Enter
Cancel
Enter
Exit
Enter
Cancel
Enter
Exit
Set Type
Enter the value. The decimal must
be entered, even if zero.