45
TITANIUM 400 AC/DC
EN
4- Full traceability
- ON
Definition :
• A welding CORD corresponds to a welding cycle.
• The PASS corresponds to welding over the entire perimeter of the part to be welded.
• The WELD is the end junction of the two joined up plates. The weld is therefore made of
one or more passes.
• The PROJECT is made of one or more finished welds.
• Temperature
*
ON : Temperature of the plate to be welded at the beginning of the cord.
• Length* ON : Cord length
*
the measurement units are displayed based on the selection defined in PARAMETERS/Units.
Pass (ON/OFF)
Welding (ON/OFF)
Temperature (ON/OFF)
Length (ON/OFF)
5- Project/bead display
6-
Identification
7- Validation
At the top left, the project name and
bead number are displayed.
(The bead number is automatically
incremented and cannot be modified)
At each end of the cord, an identifica
-
tion window is displayed: Pass number,
Weld number, Temperature of the plate
and/or length of the cord.
The validation can be done using the
interface or by pulling the trigger.
The «Explore» function allows you to access the list of work sessions created, sort them and also delete them.
The pictogram
shows the details of each session with the following information: sampling frequency, number of recorded beads, total
welding time, welding current supplied, configuration of each bead (process, time stamp, welding time and welding U-I).
The transfer of this information is done by exporting the data to a USB key.
The CSV data can be processed using spreadsheet software (Microsoft Excel
®
, Calc OpenOffice
®
, etc.).
ERROR MESSAGE, ANOMALIES, CAUSES AND SOLUTIONS
This device integrates a default management system. In the event of a failure, the following error messages may appear:
ERROR CODE / SYMPTOMS
CAUSES
SOLUTIONS
OVERVOLTAGE FAULT
Check the electrical installation
Mains voltage out of tolerance.
Have your electrical installation checked by an
authorised person. The voltage between the
3 phases must be between 340 Veff and 460
Veff.
UNDERVOLTAGE FAULT
Check the electrical installation
Mains voltage out of tolerance.
PHASE FAULT
Check the electrical installation
The installation has a missing or unbalanced
phase