FUNCTION, MENU AND PICTOGRAM DESCRIPTIONS 

 

FUNCTIONS 

Description 

Pictogram 

Function available on 

Comment 

TIG 

DC 

TIG 

AC 

MMA 

Welding current 

Current 

 

 

 

X 

Value of the welding current needed 

depends on the thickness and the type 

of metal, as well as on the welding 

joint. (A) 

HotStart 

HotStart 

 

 

 

Adjustable overcurrent at the beginning 

of the welding (%) 

ArcForce 

ArcForce 

 

 

 

Overcurrent delivered to avoid sticking 

when the electrode enters the welding 

pool (%) 

Polarity reversal 

 

 

 

 

Easy reversal of the polarity in order to 

weld with different type of electrodes 

HF arcing 

HF 

 

Ignition without contact 

LIFT arcing 

LIFT 

 

Ignition with contact 

Pre-Gas 

Pre-Gas 

 

 

Time to purge the torch and to protect 

the area with gas before ignition 

Starting current 

I Start 

 

 

Pre current  (A) 

Starting time 

T Start 

 

 

Pre current time (S) 

Up slope 

UpSlope 

 

 

Time needed to go from minimum 

current to welding current (S) 

Cold current (4TLog) 

I Cold 

 

 

Background welding current or cold 

current activated with a double button 

torch or in 4T LOG (A) 

PULSE cold current 

I Cold 

 

 

Base current or cold current in PULSE 

mode (A) 

PULSE balance 

%T Pulse 

 

 

Cold current balance (%) 

PULSE frequency 

Hz Pulse 

 

 

Pulse frequency (Hz) 

Down slope 

DownSlope 

 

 

Time needed to shift from welding 

current to minimum current, I Stop (S) 

to avoid weld defects and craters. 

Ending current 

I Stop 

 

 

 

Post Welding current (A) 

Ending time 

T Stop 

 

 

Post Welding time (S) 

Post Gas 

Post Gas 

 

 

Length of time in which gas is released 

after the arc has stopped. It protects 

the weld pool and the electrode against 

oxidization when the metal is cooling. 

AC balance 

%T AC 

 

 

 

 Wave balance control of penetration 

and cleaning (%) 

AC frequency 

Hz AC 

 

 

 

Welding frequency in AC (Hz) 

Electrode diameter 

Ø 

 

 

Diameter of the electrode tungsten 

recommended to optimize the arcing 

and the welding of certain thickness of 

metal in SYNERGIC mode  

Metal to weld 

Fe, CrNi, 

Cu/CuZn, 

AlMg, AlSi, 

Al99 

 

 

Selction of the metal to weld: Steel, 

Nickel-Chromium, Cusi or brass, 

Aluminium-Magnesium, Aluminium-

Silicon in SYNERGIC mode 

Butt weld 

 

 

 

SYNERGIC mode 

Fillet weld 

 

 

 

SYNERGIC mode 

 

 

Содержание TIG 250 AC/DC

Страница 1: ...73502 V5 23 01 15 TIG 250 AC DC SYNERGIC TIG...

Страница 2: ...FIG 1 FIG 2...

Страница 3: ...ity Lower or equal to 50 at 40 C 104 F Lower or equal to 90 at 20 C 68 F Up to 2 000m above the sea level 6500 feet Do not use this equipment to thaw pipes to charge batteries or to start any engine I...

Страница 4: ...arks can create fire or explosion Grinding work must not be carried out close to this welding equipment Gas cylinders Gas leaking from the cylinder can create a hazard if present in high concentration...

Страница 5: ...pecting the standards in place for each Installing an earth connection to the workpiece may reduce the disturbances and will not increase the risk to the operator or any other electrical appliances Th...

Страница 6: ...if the power supply tension is under 360V or over 440V or if a phase is missing To indicate this default the screen displays Once in protection mode you have to unplug the device and plug it back int...

Страница 7: ...rrent or cold current activated with a double button torch or in 4T LOG A PULSE cold current I Cold X X Base current or cold current in PULSE mode A PULSE balance T Pulse X X Cold current balance PULS...

Страница 8: ...X X Allow the modification of the password Reset parameters RESET X X X Allow to restore the original parameters Identification ID X X X After Sales module to identify the machine Backup menu X X X Me...

Страница 9: ...0 X TIG WELDING TIG mode Connection and advice Connect the earth clamp to the positive plug Connect the torch to the negative plug the trigger cable and the gas hose Ensure that the torch is equipped...

Страница 10: ...G Pulse Pulse This welding mode is an independant process different from welding on standard DC or AC It is not available on 4T LOG The pulses match the alternated increase and decrease of the current...

Страница 11: ...o set the range of welding current without deteriorating it 4 The thickness of the metal to weld SYNERGIC This mode can be of help to easily set weld parameters when you have just bought the machine A...

Страница 12: ...In order to make the electrode positionning easier a low current is supplied acting like a light beam Adjust Ideal Position 2 Release trigger elevation of the current to the hot welding current displ...

Страница 13: ...n Save as with the pictogram Save a configuration If the configuration saved is not accurate anymore and some modifications have been done in the file menu the function Save overwrite the old configur...

Страница 14: ...ction 1 Plug the remote control into the connection in the front 2 The machine will detect automatically the remote control and open the following menu 3 Select your type of remote control Connector t...

Страница 15: ...current context This voltage must be between 0 and 3 3V per 0 5V stages corresponding to a recall program Current context 0 0 5V Program 1 0 5 1V Program 2 1 0 1 5V Program 3 1 5 2V Program 4 2 2 5V P...

Страница 16: ...al injuries Protect yourself and others Ensure the following safety precautions are taken Arc radiation Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379 Rain steam...

Страница 17: ...filling of the tank the error message is still on The cooling liquid system is still not working and the fan is not on Check the fuse The unit is protected against underloads overloads and phase missi...

Страница 18: ...e Garantie wird f r Verschlei teile z B Kabel Klemmen Vorsatzscheiben etc sowie bei Gebrauchsspuren bernommen Das betreffende Ger t bitte immer mit Kaufbeleg und kurzer Fehlerbeschreibung ausschlie li...

Страница 19: ...se power supply 50 or 60Hz Dreiphasige Netzversorgung mit 50 oder Uo Tension assign e vide Rated no load voltage Leerlaufspannung U1 Tension assign e d alimentation rated supply voltage Netzspannung I...

Страница 20: ...de volume de 1l min 25 C Cooling power indicated by volumetric flow of 1l min at 25 C K hlleistung Volumenstrom von 1l min bei 25 C p max MPa bar Pression maximale Maximum pressure Maximaldruck MPa b...

Страница 21: ...CIRCUIT DIAGRAM TIG 250 AC DC TRI 21 24...

Страница 22: ...SPARE PARTS I II III 22 24...

Страница 23: ...1508 7a Option Connecteur male male connector Stecker 45699 8 Connecteur torche Torch connection Anschlu Brennertasterleitung 51120 8a Included air jack car 2 5 t 51119 9 Coupleur gaz BSP20 BSP20 gas...

Страница 24: ...ng 97206C 24 Circuit SMI secondaire Secondary IMS sekund res Leistungsteil 97280C 25 Module IGBT IGBT module IGBT Modul 52202 26 Circuit secondaire Secondary circuit board Sekund rplatine 97097C 27 Tr...