GYS TIG 250 AC/DC Скачать руководство пользователя страница 3

 

Safety instructions 

 

Thank you for choosing this machine! To get the best use from your machine please read the following carefully. 

This  User  Manual  is  designed  to  help  you  get  the  most  out  of  your  welding  equipment.                                                                                                                                                                                                                                   

Read and understand the following safety recommendations before using or servicing the unit. 

Any modification or maintenance not indicated in the manual must not be carried out. 

The manufacturer is not responsible for any injury to the operator or damage to the equipment or surrounding area, 

due to failure to follow the instructions detailed in this manual. 

If there is any issue or uncertainty, please consult a qualified individual to operate the equipment correctly.

 

Workplace 

 

This equipment must only be used for welding operations in accordance with the limits indicated on the descriptive 

panel and/or in the user manual. The operator must respect the safety precautions that apply to this type of 

welding. The manufacturer is not responsible for any incorrect or dangerous operation. 

 

According to the standard IEC 60974-10, this class A device is designed to be used in an industrial or professional 

environment. 

It can be difficult to ensure electromagnetic compatibility, due to conducted disturbances as well as radiation. 

 

This equipment must be used and stored in a place protected from dust, acid or any other corrosive. Operate the 

machine in an open, or well-ventilated area. 

 

Operating temperature: 

Use between 10 and +40°C (+14 and +104°F). 

Store between -25 and +55°C (-13 and 131°F). 

 

Air humidity: 

Lower or equal to 50% at 40°C (104°F). 

Lower or equal to 90% at 20°C (68°F). 

Up to 2,000m above the sea level (6500 feet). 

Do not use this equipment to thaw pipes, to charge batteries, or to start any engine. 

 

 

Individual protection 

 

Arc welding can be dangerous and can cause serious and even fatal injuries.  

Protect yourself and protect others. 

 

Welding exposes the user to dangerous heat, arc rays, electromagnetic fields, noise, gas fumes, and electrical 

shocks. People wearing pacemakers are advised to see their doctor before using this device. 

 

In order to protect against burns and arc eye, protective clothing should be worn at all times: fire-proof  clothing 

(cotton, overalls or jeans), protective gloves and a fire-proof apron, ensuring whole body is covered. 

 

Wear protective gloves which guarantee you an electrical and thermal insulation. 

 

It may be necessary to install fireproof welding curtains to protect others against arc rays, weld spatters and sparks. 

                                                                                                                                                                                                                                                                                                                                         

Inform the people around the working area to not look at the arc ray or the molten metal and to wear protective 

clothes. 

 

It is necessary to protect yourself with a welding hood (rated NR.10 or higher) and to protect your eyes during the 

operation. 

 

Do not operate whilst wearing contact lenses. 

 

Ensure ear protection is worn by the operator and anyone in the surrounding area if  the work exceeds the 

authorised noise limit. 

 

DO NOT TOUCH moving parts (e.g. engine, fan...) with hands, hair, clothes etc... 

The rollers must not be touched when the wire feeder is working. 

 

Never remove the safety cover of the wire feeder when the machine is plugged in -  The manufacturer is not 

responsible for any accident or injury that happens as a result of not following these safety precautions. 

 

 

Содержание TIG 250 AC/DC

Страница 1: ...73502 V5 23 01 15 TIG 250 AC DC SYNERGIC TIG...

Страница 2: ...FIG 1 FIG 2...

Страница 3: ...ity Lower or equal to 50 at 40 C 104 F Lower or equal to 90 at 20 C 68 F Up to 2 000m above the sea level 6500 feet Do not use this equipment to thaw pipes to charge batteries or to start any engine I...

Страница 4: ...arks can create fire or explosion Grinding work must not be carried out close to this welding equipment Gas cylinders Gas leaking from the cylinder can create a hazard if present in high concentration...

Страница 5: ...pecting the standards in place for each Installing an earth connection to the workpiece may reduce the disturbances and will not increase the risk to the operator or any other electrical appliances Th...

Страница 6: ...if the power supply tension is under 360V or over 440V or if a phase is missing To indicate this default the screen displays Once in protection mode you have to unplug the device and plug it back int...

Страница 7: ...rrent or cold current activated with a double button torch or in 4T LOG A PULSE cold current I Cold X X Base current or cold current in PULSE mode A PULSE balance T Pulse X X Cold current balance PULS...

Страница 8: ...X X Allow the modification of the password Reset parameters RESET X X X Allow to restore the original parameters Identification ID X X X After Sales module to identify the machine Backup menu X X X Me...

Страница 9: ...0 X TIG WELDING TIG mode Connection and advice Connect the earth clamp to the positive plug Connect the torch to the negative plug the trigger cable and the gas hose Ensure that the torch is equipped...

Страница 10: ...G Pulse Pulse This welding mode is an independant process different from welding on standard DC or AC It is not available on 4T LOG The pulses match the alternated increase and decrease of the current...

Страница 11: ...o set the range of welding current without deteriorating it 4 The thickness of the metal to weld SYNERGIC This mode can be of help to easily set weld parameters when you have just bought the machine A...

Страница 12: ...In order to make the electrode positionning easier a low current is supplied acting like a light beam Adjust Ideal Position 2 Release trigger elevation of the current to the hot welding current displ...

Страница 13: ...n Save as with the pictogram Save a configuration If the configuration saved is not accurate anymore and some modifications have been done in the file menu the function Save overwrite the old configur...

Страница 14: ...ction 1 Plug the remote control into the connection in the front 2 The machine will detect automatically the remote control and open the following menu 3 Select your type of remote control Connector t...

Страница 15: ...current context This voltage must be between 0 and 3 3V per 0 5V stages corresponding to a recall program Current context 0 0 5V Program 1 0 5 1V Program 2 1 0 1 5V Program 3 1 5 2V Program 4 2 2 5V P...

Страница 16: ...al injuries Protect yourself and others Ensure the following safety precautions are taken Arc radiation Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379 Rain steam...

Страница 17: ...filling of the tank the error message is still on The cooling liquid system is still not working and the fan is not on Check the fuse The unit is protected against underloads overloads and phase missi...

Страница 18: ...e Garantie wird f r Verschlei teile z B Kabel Klemmen Vorsatzscheiben etc sowie bei Gebrauchsspuren bernommen Das betreffende Ger t bitte immer mit Kaufbeleg und kurzer Fehlerbeschreibung ausschlie li...

Страница 19: ...se power supply 50 or 60Hz Dreiphasige Netzversorgung mit 50 oder Uo Tension assign e vide Rated no load voltage Leerlaufspannung U1 Tension assign e d alimentation rated supply voltage Netzspannung I...

Страница 20: ...de volume de 1l min 25 C Cooling power indicated by volumetric flow of 1l min at 25 C K hlleistung Volumenstrom von 1l min bei 25 C p max MPa bar Pression maximale Maximum pressure Maximaldruck MPa b...

Страница 21: ...CIRCUIT DIAGRAM TIG 250 AC DC TRI 21 24...

Страница 22: ...SPARE PARTS I II III 22 24...

Страница 23: ...1508 7a Option Connecteur male male connector Stecker 45699 8 Connecteur torche Torch connection Anschlu Brennertasterleitung 51120 8a Included air jack car 2 5 t 51119 9 Coupleur gaz BSP20 BSP20 gas...

Страница 24: ...ng 97206C 24 Circuit SMI secondaire Secondary IMS sekund res Leistungsteil 97280C 25 Module IGBT IGBT module IGBT Modul 52202 26 Circuit secondaire Secondary circuit board Sekund rplatine 97097C 27 Tr...