GYS TIG 250 AC/DC Скачать руководство пользователя страница 6

 

 

DESCRIPTION 

Thank you for choosing this machine! To get the best use from your machine please read the following carefully.  

The TIG 250 AC/DC is a portable, single phase, ventilated Inverter welding unit to be used with non consumable 

electrode (TIG)  in direct (DC) or alternative (AC) current.  TIG welding requires a gas shield protection  of 

pure(Argon). In MMA mode, it allows you to weld with any kind of electrodes: rutile, basic, stainless steel or cast 

iron. 

The TIG 250 AC/DC can be equipped with a remote control or foot pedal. 
The TIG 250 AC/DC has an integrated liquid cooling system to connect liquid cooled torches. 

 

POWER SUPPLY – STARTING UP

 

 

This machine is delivered with a 5 pin three-phase plug (3P + N + PE) 400V 16A type CEE17. The TIG 250 AC/DC 

must be connected to a 400 V socket (50 - 60 Hz) WITH earth protected by a 16A circuit breaker and a 30mA 
overcurrent discontactor. 

The absorbed current (I1eff) is indicated on the device, for its maximum setting. 

Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the 

current needed by the machine. In some countries, it may be necessary to change the plug to allow the 

use at maximum settings.

 

 

This unit has  an internal  cooling liquid system  which has 2 main functions:  the cooling of the water torch if 

connected and the cooling of internal spare parts.  So the tank of the unit needs to be filled to the maximum line 

indicated at the back of the machine.  

 

The starting up is made by pushing on the standby button.

 

 

 

The device turns into protection mode if the power supply tension is under 360V or over 440V or if a 

phase is missing. To indicate this default, the screen displays. Once in protection mode, you have to 
unplug the device and plug it back into  a socket delivering the correct voltage  (see the table of error 
messages).

 

 

Fan:  in  MMA  mode,  the fan works nonstop. In TIG  mode,  the fan works only when welding,  then stops after 

cooling. 

 

These are Class A devices. They are designed to be used in an industrial or professional environment. In a

 

different environment, it can be difficult to ensure electromagnetic compatibility due to conducted 

disturbances as well as radiation

. They comply with the norm CEI 61000-3-12. 

 

DEVICE PRESENTATION  (FIG-1)

 

  potentiometers 

 + polarity plug 

 - polarity plug 

 Gas connection for torch 

 Trigger connection 

 Water input for water cooled torch 

 Water output for water cooled torch 

 Remote control connection 

 5A fuse support 

 ON / OFF switch 

 Power cable 

 Tank 

 Gas inlet 

 

CONTROL BOARD (IHM) (FIG-2) 
 
The control board is made of a colour TFT screen and two potentiometers. How it works in 3 states: 
State 1 or  Standby mode:  with the potentiometer 1  you will be able to set the welding current,  and with the 
potentiometer 2 the parameters related to the welding current. 
State 2 or Welding mode: by pushing the potentiometer 1 you will have access to the top menu. Then by turning the 
button you will select the welding mode. You will exit this menu by waiting 8s or by pushing the potentiometer 2 -> 
back to State 1. 
State 3 or  Welding parameters mode:  by pushing the potentiometer 2  you will have access to the welding 
parameters and you will see the selection by turning the button. You will exit this menu by waiting 8s or by pushing 
the potentiometer 2 -> back to State 1. 

 

 

Содержание TIG 250 AC/DC

Страница 1: ...73502 V5 23 01 15 TIG 250 AC DC SYNERGIC TIG...

Страница 2: ...FIG 1 FIG 2...

Страница 3: ...ity Lower or equal to 50 at 40 C 104 F Lower or equal to 90 at 20 C 68 F Up to 2 000m above the sea level 6500 feet Do not use this equipment to thaw pipes to charge batteries or to start any engine I...

Страница 4: ...arks can create fire or explosion Grinding work must not be carried out close to this welding equipment Gas cylinders Gas leaking from the cylinder can create a hazard if present in high concentration...

Страница 5: ...pecting the standards in place for each Installing an earth connection to the workpiece may reduce the disturbances and will not increase the risk to the operator or any other electrical appliances Th...

Страница 6: ...if the power supply tension is under 360V or over 440V or if a phase is missing To indicate this default the screen displays Once in protection mode you have to unplug the device and plug it back int...

Страница 7: ...rrent or cold current activated with a double button torch or in 4T LOG A PULSE cold current I Cold X X Base current or cold current in PULSE mode A PULSE balance T Pulse X X Cold current balance PULS...

Страница 8: ...X X Allow the modification of the password Reset parameters RESET X X X Allow to restore the original parameters Identification ID X X X After Sales module to identify the machine Backup menu X X X Me...

Страница 9: ...0 X TIG WELDING TIG mode Connection and advice Connect the earth clamp to the positive plug Connect the torch to the negative plug the trigger cable and the gas hose Ensure that the torch is equipped...

Страница 10: ...G Pulse Pulse This welding mode is an independant process different from welding on standard DC or AC It is not available on 4T LOG The pulses match the alternated increase and decrease of the current...

Страница 11: ...o set the range of welding current without deteriorating it 4 The thickness of the metal to weld SYNERGIC This mode can be of help to easily set weld parameters when you have just bought the machine A...

Страница 12: ...In order to make the electrode positionning easier a low current is supplied acting like a light beam Adjust Ideal Position 2 Release trigger elevation of the current to the hot welding current displ...

Страница 13: ...n Save as with the pictogram Save a configuration If the configuration saved is not accurate anymore and some modifications have been done in the file menu the function Save overwrite the old configur...

Страница 14: ...ction 1 Plug the remote control into the connection in the front 2 The machine will detect automatically the remote control and open the following menu 3 Select your type of remote control Connector t...

Страница 15: ...current context This voltage must be between 0 and 3 3V per 0 5V stages corresponding to a recall program Current context 0 0 5V Program 1 0 5 1V Program 2 1 0 1 5V Program 3 1 5 2V Program 4 2 2 5V P...

Страница 16: ...al injuries Protect yourself and others Ensure the following safety precautions are taken Arc radiation Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379 Rain steam...

Страница 17: ...filling of the tank the error message is still on The cooling liquid system is still not working and the fan is not on Check the fuse The unit is protected against underloads overloads and phase missi...

Страница 18: ...e Garantie wird f r Verschlei teile z B Kabel Klemmen Vorsatzscheiben etc sowie bei Gebrauchsspuren bernommen Das betreffende Ger t bitte immer mit Kaufbeleg und kurzer Fehlerbeschreibung ausschlie li...

Страница 19: ...se power supply 50 or 60Hz Dreiphasige Netzversorgung mit 50 oder Uo Tension assign e vide Rated no load voltage Leerlaufspannung U1 Tension assign e d alimentation rated supply voltage Netzspannung I...

Страница 20: ...de volume de 1l min 25 C Cooling power indicated by volumetric flow of 1l min at 25 C K hlleistung Volumenstrom von 1l min bei 25 C p max MPa bar Pression maximale Maximum pressure Maximaldruck MPa b...

Страница 21: ...CIRCUIT DIAGRAM TIG 250 AC DC TRI 21 24...

Страница 22: ...SPARE PARTS I II III 22 24...

Страница 23: ...1508 7a Option Connecteur male male connector Stecker 45699 8 Connecteur torche Torch connection Anschlu Brennertasterleitung 51120 8a Included air jack car 2 5 t 51119 9 Coupleur gaz BSP20 BSP20 gas...

Страница 24: ...ng 97206C 24 Circuit SMI secondaire Secondary IMS sekund res Leistungsteil 97280C 25 Module IGBT IGBT module IGBT Modul 52202 26 Circuit secondaire Secondary circuit board Sekund rplatine 97097C 27 Tr...