GYS TIG 250 AC/DC Скачать руководство пользователя страница 16

 

The integrated cooling unit is designed to detect if a water cooled torch is connected or not. Please do 

not short-circuit the cooling unit. If you do so, the machine will not be able to work to its full 

specifications. 

 

DUTY CYCLE

 

 

 

The machine  has a  specification with a “constant current output”.  The duty cycles according to the normal 

EN60974-1 (@ 40°C during 10min) are indicated in the following table: 

  

 

MMA 

TIG DC 

TIG AC 

X (40°C) 

40% 

60% 

100%  60% 

100% 

60% 

100% 

I

2

 

250A 

230A 

200A 

250A 

200A 

250A 

200A 

U

2

 

30V 

29,2V 

28V 

20V 

18V 

20V 

18V 

 

Note: the tests have been realized at 40 °C. 

 

MAINTENANCE/ ADVICE

 

 

Maintenance should only be carried out by a qualified person. 

 

Ensure the machine is unplugged, and that the ventilator inside has stopped before carrying out maintenance 

work.  (DANGER High Voltage and Currents). 

 

JBDC recommends removing the steel cover 2 or 3 times a year to remove any excess dust. Take this opportunity 

to have the electrical connections checked by a qualified person with an insulated tool. 

 

Regularly check the condition of the power supply cable. If damaged, it will need  to be replaced by the 

manufacturer, its’ after sales service or a qualified person. 

 

Ensure the ventilation holes of the device are not blocked to allow adequate air circulation. 

 

Before each use, check the state of welding cables of the torch and earth clamp (The conductive metal should not 

be exposed). 

 

SAFETY 

 

Arc w elding can be dangerous and can cause serious and even fatal injuries. 

Protect yourself and others. Ensure the follow ing safety precautions are taken: 

 

Arc radiation 

Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379.  

Rain, steam, damp 

Use your welding unit in a clean/dry environment (pollution factor ≤ 3), on a flat surface, 

and more than one meter from the welding work-piece. Do not use in rain or snow. 

 

Electric shock 

This device must only be used with an earthed power supply. Do not touch the parts 

under high voltage. Check that the power supply is suitable for this unit. 

 

Falls 

Do not place/carry the unit over people or objects. 

Burns 

Wear protective (fire-proof) clothing (cotton, overalls or jeans). 

Wear protective gloves and a fire-proof apron. 

 

Ensure other people keep a safe distance from the work area and do not look directly at 

the welding arc. 

Protect others by installing fire-proof protection curtains. 

 

Fire risks 

Remove all flammable products from the work area. Do not work in presence of 

flammable gases. 

 

Fumes 

Do not inhale welding gases and fumes. Use the device in a well ventilated environment, 

with artificial extraction if welding indoors. 

 

Additional 

Any welding operation undertaken in..... 

Precautions 

- rooms where there is an increased risk of electric shocks, 

- Poorly ventilated rooms, 

- In the presence of flammable or explosive material, 

Use should always be approved by a "responsible expert", and made in presence of 

people trained to intervene in case of emergency. 

Technical protection as described in the Technical Specification CEI/IEC 62081 must be 

implemented. Welding in raised positions should not be undertaken, except in case of 

safety platforms use. 

 

 

Содержание TIG 250 AC/DC

Страница 1: ...73502 V5 23 01 15 TIG 250 AC DC SYNERGIC TIG...

Страница 2: ...FIG 1 FIG 2...

Страница 3: ...ity Lower or equal to 50 at 40 C 104 F Lower or equal to 90 at 20 C 68 F Up to 2 000m above the sea level 6500 feet Do not use this equipment to thaw pipes to charge batteries or to start any engine I...

Страница 4: ...arks can create fire or explosion Grinding work must not be carried out close to this welding equipment Gas cylinders Gas leaking from the cylinder can create a hazard if present in high concentration...

Страница 5: ...pecting the standards in place for each Installing an earth connection to the workpiece may reduce the disturbances and will not increase the risk to the operator or any other electrical appliances Th...

Страница 6: ...if the power supply tension is under 360V or over 440V or if a phase is missing To indicate this default the screen displays Once in protection mode you have to unplug the device and plug it back int...

Страница 7: ...rrent or cold current activated with a double button torch or in 4T LOG A PULSE cold current I Cold X X Base current or cold current in PULSE mode A PULSE balance T Pulse X X Cold current balance PULS...

Страница 8: ...X X Allow the modification of the password Reset parameters RESET X X X Allow to restore the original parameters Identification ID X X X After Sales module to identify the machine Backup menu X X X Me...

Страница 9: ...0 X TIG WELDING TIG mode Connection and advice Connect the earth clamp to the positive plug Connect the torch to the negative plug the trigger cable and the gas hose Ensure that the torch is equipped...

Страница 10: ...G Pulse Pulse This welding mode is an independant process different from welding on standard DC or AC It is not available on 4T LOG The pulses match the alternated increase and decrease of the current...

Страница 11: ...o set the range of welding current without deteriorating it 4 The thickness of the metal to weld SYNERGIC This mode can be of help to easily set weld parameters when you have just bought the machine A...

Страница 12: ...In order to make the electrode positionning easier a low current is supplied acting like a light beam Adjust Ideal Position 2 Release trigger elevation of the current to the hot welding current displ...

Страница 13: ...n Save as with the pictogram Save a configuration If the configuration saved is not accurate anymore and some modifications have been done in the file menu the function Save overwrite the old configur...

Страница 14: ...ction 1 Plug the remote control into the connection in the front 2 The machine will detect automatically the remote control and open the following menu 3 Select your type of remote control Connector t...

Страница 15: ...current context This voltage must be between 0 and 3 3V per 0 5V stages corresponding to a recall program Current context 0 0 5V Program 1 0 5 1V Program 2 1 0 1 5V Program 3 1 5 2V Program 4 2 2 5V P...

Страница 16: ...al injuries Protect yourself and others Ensure the following safety precautions are taken Arc radiation Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379 Rain steam...

Страница 17: ...filling of the tank the error message is still on The cooling liquid system is still not working and the fan is not on Check the fuse The unit is protected against underloads overloads and phase missi...

Страница 18: ...e Garantie wird f r Verschlei teile z B Kabel Klemmen Vorsatzscheiben etc sowie bei Gebrauchsspuren bernommen Das betreffende Ger t bitte immer mit Kaufbeleg und kurzer Fehlerbeschreibung ausschlie li...

Страница 19: ...se power supply 50 or 60Hz Dreiphasige Netzversorgung mit 50 oder Uo Tension assign e vide Rated no load voltage Leerlaufspannung U1 Tension assign e d alimentation rated supply voltage Netzspannung I...

Страница 20: ...de volume de 1l min 25 C Cooling power indicated by volumetric flow of 1l min at 25 C K hlleistung Volumenstrom von 1l min bei 25 C p max MPa bar Pression maximale Maximum pressure Maximaldruck MPa b...

Страница 21: ...CIRCUIT DIAGRAM TIG 250 AC DC TRI 21 24...

Страница 22: ...SPARE PARTS I II III 22 24...

Страница 23: ...1508 7a Option Connecteur male male connector Stecker 45699 8 Connecteur torche Torch connection Anschlu Brennertasterleitung 51120 8a Included air jack car 2 5 t 51119 9 Coupleur gaz BSP20 BSP20 gas...

Страница 24: ...ng 97206C 24 Circuit SMI secondaire Secondary IMS sekund res Leistungsteil 97280C 25 Module IGBT IGBT module IGBT Modul 52202 26 Circuit secondaire Secondary circuit board Sekund rplatine 97097C 27 Tr...

Отзывы: