24
POWERDUCTION 50LG
EN
Translation of the original instructions
«PURGE» MODE
1.
To replace the cooling liquid, perform the same action than when changing the accessory until the step « unswcrew
the accessory » (n°3).
2.
Push the heat authorisation button (2) for 3 seconds until it switches on.
3.
Place the lance on top of a recipient of at least 10 liter capacity (e.g. bucket).
4.
Press the lance button (11).
The pump starts and will stop once the flow becomes inferior to 1 l/minute or after 2 minutes.
The display indicates the flow in deciliters.
5.
To stop the pump, press any button.
6.
Refill the tank with new cooling liquid (Cooling liquid :
CORAGARD CS 330 7 l).
7.
Screw the inductor back on.
8.
Press the button (10).
The cooling circuit is performing a purge cycle.
If the flow is correct, the machine emits a double «BEEP» and the product is ready to operate.
Otherwise a fault is displayed (refer to the fault code table on the previous page).
It is recommended to change the cooling liquid every two years, otherwise you may damage the Powerduction’s lance.
COOLING CIRCUIT AND «FORCED COOLING» MODE
To prevent the cooling liquid’s temperature from rising, the cooling fan starts, in any event, when the liquid’s tempera
-
ture reaches 35°C (95°F). As soon as the temperature goes below that, the cooling fan switches off.
During long periods of use, the POWERDUCTION has a forced cooling mode. To activate it :
1.
Set the main switch (1) to ON.
The machine initialises in 2 seconds.
2.
Press the activation button (2) as described on page 5. The indicator on button (2) and the lance support LED (12) both
switch on, indicating that the machine is ready to operate.
3.
Hold (>3 seconds) the button (10). The « Forced cooling» mode is activated.
The cooling fan then starts automatically. The cooling fan will be audible and the «Fan ON» message will appear on the
display.
To stop the «Forced cooling», press the activation button to stop the heating or hold the button (10) again. The message
«Fan OFF» is displayed.
MAINTENANCE
General recommendations
• It is recommended to change the cooling liquid every two years, otherwise you may damage the Powerduction’s lance.
• It is essential that the maintenance of the product is performed by qualified, authorised staff, that is fully aware of the
recommendations outlined in this manual.
• Never clean, lubricate or perform maintenance on the product when it’s being used.
• Before any maintenance work, set the On / Off switch to « 0 » to switch off the machine, .then disconnect it it from
the mains power supply to prevent any electrical shock or other risks resulting from improper handling.
• Do not wear rings, watches, jewellery, hanging clothes (e.g. ties), torn clothes, scarves, unbuttoned or unzipped
jackets, or anyhting that could get caught during the operation of the machine
• Rather wear clothing specifically designed for the prevention of accidents, such as: non-slip shoes, anti-noise helmets,
protective goggles, safety shoes, etc ...
• Never use petrol or flammable solvents to clean the product. Prefer the use of water and, if necessary, non toxic com
-
mercial solvents.
• After maintenance, always put and secure the metal covers back on, before switching the machine on.
•
The ferrite on inducer can be replaced if damaged.