Operator's Guide
3 Digitizer status information
The digitizer outputs various status information to report the
system operation such as GPS and time synchronisation status.
This status information is in plain ASCII text packaged in the
same block structure as the channel data. There are usually 12
lines of information in a block.
To access a Status window right click on the Stream ID ‘****00’,
(where **** is the digitizer). In the example below this is
102600
Notice this is the only stream with ‘0’samples per second
During boot-up the units report their module type, firmware
revision number, the system-id and serial number. This
information is followed by the count of resets that have
occurred and the time of this re-boot from the internal back-up
clock. The following lines report the configuration of the unit
sample rates, output taps selected, and the baud-rates of the
serial ports.
Typical digitizer re-boot status message:
July 2016
11
Firmware revision
System
type
System ID & serial number
Internal clock
Sample rates
DSP filter version
Selected tap, sample
rate and channel
Data port baud rate
GPS port baud rate
Содержание CMG-DM16R8