CSA Enclosure 3 – CAUTION: TEST THE GROUND FAULT INTERRUPTER BEFORE EACH USE
OF THE SPA. TOUJOURS VERIFIER L'EFFICACITE DU DISJONCTEUR DIFFERENTIEL AVANT
D'UTILISER LE BAIN. BONDING LUGS. COSSES DEMISE A LA MASSE.
USE THE COPPER
CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUTEURS DE CUIVRE.
WARNING: DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING. AVERTISSEMENT:
DISCONNECTER DU CIRCUIT D'ALIMENTATION ELECTRIQUE AVENT L'ENTRETIEN. BEFORE
OBTAINING ACCESS TO TERMINALS, ALL SUPPLY CIRCUITS MUST BE DISCONNECTED.
EN60335-1 and EN60335-2-60.
230vac/50Hz. 2x16A Single Phase. IPX5. Spa Model. Gulf Coast
Spa Manufacturers
Parts containing live parts supplied with safety extra low voltage not exceeding 12v must be
inaccessible to a person in the bath. Earthed appliances must be permanently connected to fixed
wiring. Parts incorporating electrical components, except remote control devices, must be located or
fixed so that they cannot fall into the bath. Appliances should be supplied through a residual current
device (RCD) having a rated residual operating current not exceeding 30ma.
Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
7