PROGRAMMING FILTER CYCLES
The system automatically performs two cycles per day, at 12-hour intervals. During a filter cycle:
- Pump 2 and Blower run at high speed for one minute;
- Pump 1 runs at low speed for a programmed number of hours;
- Ozonator is turned on.
To set the filter cycle duration:
Press and hold
Light
key
for 5 sec. The display will
show
xx
, with “xx”
representing the number of
hours Pump 1 will be
running at low speed.
Use
Up
or
Down
arrow key
to change setting.
00 = no filtration
12 = continuous filtration.
When the desired setting is
displayed, press Light key
again to confirm.
The “Filter Cycle” indicator
lights up when a filter cycle
is on.
An irregularly flashing “Filter Cycle” indicator means that the system has stopped filtering after 3 hours
because water temp, exceeds Set Point by more than 2
°
F (1
°
C). If temperature cools down before
the scheduled end of the cycle, filtering will resume for the remainder of the programmed cycle.
Note: After a power failure, the filter cycle duration will return to its default value (6 hours). In this
case, the first filter cycle will start 12 hours after power has been restored. The filter cycle will be
suspended if the user enters the spa and activates a pump or blower manually. This is to prevent
unnecessary operation of the ozonator. The cycle will be suspended for 40 minutes beyond the last
manual activation of any accessory. The filter indicator will flash on the display while the filter cycle is
suspended.
GULF COAST MANUFACTURERS
EQUIPMENT PACK
Heating Housing and Heater Element Inside Tube
Color Coded Spa
Equipment Hook
ups.
Pressure Switch
16
Содержание 10000/BOCA GRANDE
Страница 14: ...14 14 ...