Customer Helpline 0333 3201989
12
Maintenance
Trouble Shooting
Remove the plug from the socket before carrying out any adjustment, servicing or
maintenance.
There are no user serviceable parts in your power tool. Never use water or chemical
cleaners to clean your power tool. Wipe clean with a dry cloth. Always store your power
tool in a dry place. Keep the motor ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the ventilation slots. This is normal
and will not damage your power tool.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
LUBRICATION TOOL (SEE FIG I)
The tool is grease-lubricated. A grease refill is only required during hammer work
efficiency is low. Open the grease box lid at the top of the hammer using the pin spanner
provided. Then refill approx 30g grease provided with your tool. The grease specification
is general purpose lithium based.
Caution: Keep the container of grease away from children.
1. If your power tool does not start, check the plug on the power supply first.
2. If your hammer becomes too hot in use, set the hammer switch to the drill mode and
allow your drill to operate at maximum speed without load for 2 minutes.
3. If your hammer work efficiency is too low, please add sufficient grease in the grease
box.
4. If work efficiency is too low please check drill bit or chisel and make sure it is not
blunt or worn.
5. If a fault can not be rectified, return the tool to an authorized dealer for repair.