background image

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 20-0183-1

Страница 1: ... 1 ...

Страница 2: ...guidance eu com Web www guidance eu com customer support Copyright 2016 Guidance Marine Limited All Rights Reserved Copyright in the whole and every part of this document belongs to Guidance Marine Limited the Owner and may not be used sold transferred copied or reproduced in whole or in part in any manner or form or in or on any media to any person other than in accordance with the terms of the O...

Страница 3: ...ngeGuard Software 15 System Software Overview 15 Getting Started 15 Configuring the System Parameters 17 Control Panel General Parameters 18 Control Panel Sensors Screen 19 Sensor Parameters 19 Control Panel Vessel Screen 20 Control Panel Alarms Screen 22 Default Limits Alarms 22 Alarm Limits Individual sensor setting 23 Control Panel Security Screen 24 Control Panel Licence Screen 24 Control Pane...

Страница 4: ...n how to use the system please see 94 0447 4 RangeGuard Operator s Guide Note that the installation of a RangeGuard system is application specific assistance from Guidance Marine may be required to achieve optimal performance The RangeGuard system is subject to further development Whilst we endeavour to describe its functionality correctly we do not guarantee that this document exactly represents ...

Страница 5: ... the outside of a vessel and are connected to the controller via screened Cat 5e cable up to a maximum length of 100m RangeGuard sensors have a fixed elevation beam width of 11 5 5 and are available in two azimuth beam options 1 Wide beam 110 2 Narrow beam 11 By default the sensors measure the range of the nearest obstacle but can instead measure to selected objects that are further away by changi...

Страница 6: ...Asset Protection Vessel protection drive off detection Offshore supply vessel station keeping Wind farm dynamic positioning Salvage monitoring athwart speed and during fender operations Docking Assist Blind spot detection Blind Spot Augmentation when used with video Ship to Ship LNG transfer athwart speed and distance detection Autonomous vessel applications Training Aid confirmation of manually e...

Страница 7: ...otes RangeGuard Controller 21 0391 1 RangeGuard Wide Beam Sensor 20 0183 1 RangeGuard Narrow Beam Sensor 20 0184 1 Ethernet Cable 90m length ToughCat 33 0456 3 24 AWG Ethernet Cable 40m length 33 0124 3 Up to 4 RangeGuard sensors Narrow or wide beam RangeGuard Controller Ethernet Cable ...

Страница 8: ...al numbers for components of the RangeGuard system can be found as follows The RangeGuard system version is reported in the top right hand corner of the user screen RangeGuard Controller Located at the back of the Controller RangeGuard Sensor Located at the back of each sensor ...

Страница 9: ...of 100m for each connection between the controller and a sensor Prior to installation a vessel survey focussing on the cable routing is recommended in order to ensure that the chosen location of the RangeGuard controller conforms to the above cabling limitations It is recommended that the RangeGuard System be connected to the ships supply via a filtered UPS Any video equipment associated with the ...

Страница 10: ...ide beam sensors reporting range Wind farm dynamic positioning Two wide beam sensors mounted on the operations side of the vessel with a maximum separation of 20m Salvage monitoring athwart speed and during fender operations Narrow beam sensor horizontally mounted between fenders and adjacent to the centreline of the vessel Berthing aid Horizontally stern and shoulder mounted and adjacent to the c...

Страница 11: ...s should be mounted well clear of VHF emergency band antennas RangeGuard sensors should be positioned to avoid irradiation by S or X band radar RangeGuard sensors should have an unobstructed view of the area or object being monitored Sensor Dimensions Front View Top View ...

Страница 12: ...System 12 The rear of the sensor has 4 mounting holes that are used to secure the sensor onto a standard mounting plate This can be affixed to a custom bracket in order to locate the sensor anywhere on the vessel as required Side View Rear View ...

Страница 13: ...th of cable for any sensor cable is 100m The length and integrity of the cable should be confirmed using an Ethernet data cable tester on completion of connecting the RJ45 plugs The cable should be shielded flexible multi strand twisted pair cable Cat5e or similar with a minimum wire gauge of 24AWG System Installation Wiring Connections PIN Both Ends Signal Wire Colour 1 IF White Orange 2 0V IF Or...

Страница 14: ...ntroller Installed on Bridge T3MP PSU 240 to 12V Bridge UPS RJ45 RJ45 RJ45 RJ45 USB x 3 12V DC I P VGA LAN1 Any computer on the shared network DAC USB 240 V AC Euro plug RangeGuard Controller Sensor 1 Sensor 2 Sensor 3 Sensor 4 Vessel Network Not Supplied ...

Страница 15: ...e loaded with the RangeGuard Display All such systems must be Windows 7 based and connected to the same network as the RangeGuard controller Getting Started Opening User Interface directly from within the RangeGuard Controller The RangeGuard controller has an integral PC which can be used to display the User Interface Connect a Keyboard and Mouse to the available USB ports and a Monitor to the VGA...

Страница 16: ... standard network Either way the connecting laptop must have its Local Area Connection set to the same subnet as the RangeGuard controller 192 168 2 xxx The controller is set to 192 168 2 231 so xxx must be a value other than 231 The subnet mask should be set to 255 255 255 0 Interfacing Data to Third Party Systems Data can be made available for third party systems either via an HTTP request or Se...

Страница 17: ...t should not be necessary to modify these except for Label and Field of View To access the configuration screens click on the Settings button spanner symbol near the top right corner of the main screen Enter the configuration settings password into the dialog box The password is initially password Then click the Login button The RangeGuard Control Panel will be displayed ...

Страница 18: ...s 1024 MB If the controller unit is not supplied with an integral PC then this value can be reduced to limit the disk space that the RangeGuard system uses for logging Debug log size limit Default value is 1024 MB If the controller unit is not supplied with an integral PC then this value can be reduced to limit the disk space used for debug logging Choose display units appropriate for the applicat...

Страница 19: ...d of View Set to 10 or 110 degrees This value sets the conical shape displayed on the Bird s Eye View of the RangeGuard Display to represent the radar beam from this sensor The value must correspond to the sensor type fitted wide or narrow beam Gain This is set according to the application and typical operating conditions Changing this value from the default of 0 01 should only be done on the advi...

Страница 20: ...to install an image 1 Click on the LOAD IMAGE button 2 Click on Choose File This opens a file dialog box 3 Browse to the required image click on it and press Open 4 Click on LOAD Use the CLEAR IMAGE button to remove an image or else simply load a new image to replace the existing one After the file is loaded the size of the image on the screen may be too large or too small This can be adjusted by ...

Страница 21: ...ed directly This is a useful way to make fine adjustments enabling the commissioning engineer to accurately position the sensor on the vessel display and ensure angular alignment The X Offset Y Offset and Angle parameters are for display purposes only The Range Offset is a value that is added to the range measured by the sensor This offset is used to facilitate the positioning of the sensor within...

Страница 22: ...ts colour is shown as the background of the Range field for that sensor in Table View or Single Sensor View If both amber and red conditions are met the alarm is shown as red The Disable all alarms tick box acts as a master switch allowing all alarms to be turned off at once Default Limits Alarms Values The choice of alarms to be set is application dependant Leaving any value blank disables that i...

Страница 23: ... 2 Closing speed limits at ranges between 10m and 20m 3 Closing speed limits beyond 20m The defined values are set to allow a vessel to approach a berth or salvage vessel in a safe and efficient manner It gives early warning that action must be taken before contact is made with the quayside or an adjacent vessel Alarm Limits Individual sensor setting Individual alarm settings follow the same princ...

Страница 24: ... and for access to the configuration settings Initially these passwords are as follows Main password none login not required Settings Password password On ticking the small box in either section the user is prompted to provide a new password and to confirm it Control Panel Licence Screen The RangeGuard System will be shipped with the licence pre installed No customer action is required ...

Страница 25: ...ed here as on the main screen There is also a facility to update the RangeGuard Server software Updating Server Software To update the RangeGuard Server software 1 From the Version Screen click on the Update Software link This opens the Update Software dialog 2 Click on the Choose File button This opens a file dialog box ...

Страница 26: ...n the Open button The No file chosen string is replaced with an abbreviation of the name of the chosen file e g RangeGuard 1 252 zip 5 Click on the Upload and Restart button After a few seconds the message Loading Please wait is displayed 6 Once loading is complete Click on Back to RangeGuard 7 The RangeGuard system will then display loading as the new display is loaded ...

Страница 27: ...uld be mounted as close to the sensors as possible to match the reported range to the scene as closely as possible 3 A camera per sensor is recommended 4 Wide beam sensor viewing cameras require fish eye lenses to be able to view the same field of view as a wide beam RangeGuard sensor 5 The video system time should be synchronised to the RangeGuard system for data synchronisation 6 The camera syst...

Страница 28: ...l control on CAT 5e SCTP Sensor Control Sensor Control capable of displaying 4 sensors simultaneously Sensor Control Protocol USB from controlling computer or remotely via web browser ENVIRONMENTAL Ambient Temperature Range 25 C to 55 C Atmospheric Conditions Operates in fog heavy rain snow and ice conditions Water and Dust Protection Sensor IP67 certified Standards Compliance EN 300 440 1 and 2 E...

Страница 29: ...re compliance This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Changes or modifications not expressly approved by the party responsible Access Point Configuration Any wireless access point should be configured as follows 1 The base address of the access point should be on the same subnet as the fixed IP address of the RangeGuard system Examp...

Страница 30: ... Beam 5 O Operating Range 28 P Part Numbers 7 Password 24 Power Output 28 Product Label 12 R Range Accuracy 28 Range Offset 21 Raw Log Location 19 RF Immunity 28 S Security Screen 24 Sensor Dimensions 11 28 Label 19 Parameters 19 Power 28 Sensor Position Table 21 Serial Numbers 8 Server Software 25 Standards Compliance 28 System Specifications 28 T Temperature Range 28 Third Party Systems 16 Time ...