Actions in Bootloader mode
If the web interface of the device is no longer accessible, the device can be put into
Bootloader mode (see chapter Bootloader activation
). The following functions can be
executed using the GBL_Conf.exe application:
·
Set IPv4 address, net-mask and gateway
·
Turn HTTP password on and off
·
Turn IP-ACL on and off
·
Factory Reset
·
Allow jump from firmware to bootloader
·
Restart the device
For devices with relays, entering or exiting the bootloader mode does not change
the state of the relays as long as the operating voltage is maintained.
The GBL_Conf.exe program is available free of charge on our website www.gude.info and
can also be found on the enclosed CD-ROM.
Interface GBL_Conf
To check the network settings with GBL_Conf.exe, start the program and choose
"All
Devices"
in the
"Search"
menu. From the list select the appropriate device. The lower
part of the left half of the window now shows the current network settings of the device. If
the IP address is displayed with the default settings (192.168.0.2), either no DHCP
server is present on the network, or there could be no free IP address assigned to it.
·
Activate the Bootloader Mode (see Chapter Bootloader Mode) and choose in menu
"Search" the item "Bootloader-Mode Devices only"
·
Enter the desired settings in the edit window and save them with
"Save Config".
·
Deactivate the boot loader mode for the changes to take effect. Select again
"All
Devices"
in the
"Search"
menu of GBL_Conf.exe.
21
Содержание Expert Sensor Box 7213
Страница 2: ...2 Expert Sensor Box 7213 7214 2022 GUDESystems GmbH...
Страница 5: ...Device Description...
Страница 13: ...Operating...
Страница 23: ...Configuration...
Страница 51: ...Specifications...
Страница 94: ...Support...
Страница 100: ...100 Expert Sensor Box 7213 7214 2022 GUDESystems GmbH Expert Sensor Box 7213 7214 2022 GUDE Systems GmbH 3 16 2022...