Inspection Log

If equipment fails inspection

IMMEDIATELY REMOVE FROM SERVICE.

Date of First Use: __________________.

Product lifetime is 5 years from Date of First
Use, or, if not recorded, from Date of
Manufacture, as long as it passes pre-use and
Competent Person inspections. User must
inspect prior to EACH use. Competent Person
other than user must complete formal
inspection at least every 6 months.
Competent Person to inspect and initial.

This inspection log must be specific to one
Temper Anchor. Separate inspection logs
must be used for each Temper Anchor.
All inspection records must be made visible
and available to all users at all times.

Safety Information

Failure to understand and comply with safety regulations may result in

serious injury or death. Regulations included herein are not all-inclusive,

are for reference only, and are not intended to replace a Competent

Person’s judgment or knowledge of federal or state standards. 

!

WARNING

Do not alter equipment. Do not misuse equipment.

Workplace conditions, including, but not limited to, flame, corrosive chemicals, electrical shock, sharp objects,
machinery, abrasive substances, weather conditions, and uneven surfaces, must be assessed by a Competent
Person before fall protection equipment is selected.

The analysis of the workplace must anticipate where workers will be performing their duties, the routes they
will take to reach their work, and the potential and existing fall hazards they may be exposed to. Fall
protection equipment must be chosen by a Competent Person. Selections must account for all potential
hazardous workplace conditions. All fall protection equipment should be purchased new and in an unused
condition.

Fall protection systems must be selected and installed under the supervision of a Competent Person, and used
in a compliant manner. Fall protection systems must be designed in a manner compliant with all federal, state,
and safety regulations. Forces applied to anchors must be calculated by a Competent Person.

Unless explicitly stated otherwise, the maximum allowable free fall distance for lanyards must not exceed 6’.
No free fall allowed for non-LE SRLs. Class A SRLs must arrest falls within 24”; Class B SRLs must arrest falls
within 54”.

Harnesses and connectors selected must be compliant with manufacturer’s instructions, and must be of
compatible size and configuration. Snap hooks, carabiners, and other connectors must be selected and applied
in a compatible fashion. All risk of disengagement must be eliminated. All snap hooks and carabiners must be
self-locking and self-closing, and must never be connected to each other.

A pre-planned rescue procedure in the case of a fall is required. The rescue plan must be project-specific. The
rescue plan must allow for employees to rescue themselves, or provide an alternative means for their prompt
rescue. Store rescue equipment in an easily accessible and clearly marked area.

Содержание Temper Anchor Series

Страница 1: ...nd these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 7 Product Specific Applications 2 Limitations 2 3 Components and...

Страница 2: ...lude state regulations if applicable Consult regulatory agencies for more information on personal fall arrest systems and associated components Worker Classifications CAUTION Understand the following...

Страница 3: ...or 3 total Deceleration distance 4 total Height of harness dorsal D ring from worker s feet 6 total Required distance from anchorage 19 total Limitations Compatibility When making connections with Tem...

Страница 4: ...rking Angle From Perpendicular 6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6...

Страница 5: ...zed out from underneath fastener WARNING NEVER load anchor improperly Prior to installation refer to anchorage positioning chart pg 9 to ensure installation location will satisfy intended work applica...

Страница 6: ...s When not in use store equipment where it will not be affected by heat light excessive moisture chemicals or other degrading elements Prior to EACH use inspect Temper Anchor for deficiencies includin...

Страница 7: ...ticipate where workers will be performing their duties the routes they will take to reach their work and the potential and existing fall hazards they may be exposed to Fall protection equipment must b...

Страница 8: ...nnection per Temper Anchor IMMEDIATELY remove from use if exposed to forces of fall arrest WARNING 90040 Rev E May be used in multiple installation applications Always use new fasteners for each insta...

Отзывы: