G
ua
rd
ia
n
Fa
ll
Pr
ot
ec
tio
n
6
30
5
S.
2
31
st
S
t.
, K
en
t,
W
A
9
80
32
p
ho
ne
: (
80
0)
4
66
-6
38
5
f
ax
: (
80
0)
6
70
-7
89
2
w
w
w
.g
ua
rd
ia
nf
al
l.c
om
2
Product Specific Applications
Personal Fall Arrest:
Temper Anchor may be used to support a MAXIMUM 1 PFAS for use in Fall
Arrest applications. Structure must withstand loads applied in the directions permitted by the
system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if used in combination with
equipment explicitly certified for such use. Applicable D-ring: Dorsal.
Restraint:
Temper Anchor may be used in Restraint applications. Restraint systems prevent
workers from reaching the leading edge of a fall hazard. Always account for fully deployed length
of lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system
of at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces
with slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.
!
WARNING
Use of equipment in unintended applications may result in serious
injury or death. Maximum 1 attachment per connection point.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-420 lbs.
FALL CLEARANCE CALCULATION
Lanyard length
(6’ total)
Safety factor
(3’ total)
Deceleration
distance (4’ total)
Height of harness
dorsal D-ring from
worker’s feet
(6’ total)
Required
distance
from
anchorage
(19’ total)
Limitations
Compatibility:
When making connections with Temper Anchor, eliminate all possibility of roll-out. Roll-out
occurs when interference between a hook and the attachment point causes the hook gate to unintentionally
open and release. All connections must be selected and deemed compatible with Temper Anchor by a
Competent Person. All connector gates must be self-closing and self-locking, and withstand minimum loads of
3,600 lbs. See the following for examples of compatible/incompatible connections:
Fall Clearance:
There must be sufficient clearance
below the anchorage connector to arrest a fall
before the user strikes the ground or an obstruction.
When calculating fall clearance, account for a
MINIMUM 3’ safety factor, deceleration distance,
user height, length of lanyard/SRL, and all other
applicable factors.
Diagram shown is an example fall
clearance calculation ONLY.
Swing Falls:
Prior to installation or use, make
considerations for eliminating or minimizing
all swing fall hazards. Swing falls occur when
the anchor is not directly above the location
where a fall occurs. Always work as close to
in line with the anchor point as possible.
Swing falls significantly increase the
likelihood of serious injury or death in the
event of a fall.
Connector
closed and
locked to
D-ring.
OK.
Connector
to integral
lanyard.
NO.