MINIMUM substrate thickness: Wood: 3/4” CDX or better; Metal: 20g or better.

Applicable roof pitches: 0/12 - 12/12.

All fasteners MUST be fully embedded in substrate.

Temper Anchor MUST install flush against substrate. NEVER install onto bare rafter or truss. 
All installation must be done under the supervision of a Competent Person.

1. Determine installation location for anchor; ensure location is free of debris, rot, decay, cracking, and
hazardous materials. NEVER install on gable ends, fascias, rake ends, overhangs, bottom cords, collar boards,
spliced sections, or substrate incapable of withstanding application minimum loads.

8 Per Side:
6 in center,
1 left of center,
1 right of center.
Total: 16.

5. A Competent Person must ensure all fasteners are installed correctly. Rubber gaskets on fasteners must
be compressed against Temper Anchor. DO NOT over-tighten fasteners. Fasteners are over-tightened if
gasket breaks, or is entirely squeezed out from underneath fastener. 

!

WARNING

NEVER load anchor improperly.

Prior to installation, refer to

anchorage positioning chart (pg. 9)

to ensure installation location will

satisfy intended work application(s).

2. Make considerations for eliminating or minimizing swing
fall hazards.

3. Ensure all fasteners are those supplied by Guardian Fall Protection, or are deemed compatible by a
Competent Person.

4. Place Temper Anchor over roof ridge, and adjust to fit pitch. Depending on installation type, adhere to the
following requirements: 

• For installation onto metal and into field: use (16) screws
(8 per side), 6 in center column of Fastener Installation Holes,
in 1 hole left of center, and in 1 hole right of center. Guardian
recommends using HILTI Kwik-Pro Self-Drilling Screws.
Fasteners must be selected and deemed compatible by a
Competent Person. 

• For installation onto wood and into truss or
other compatible support beam: use (12) #12 2”
screws (6 per side) in center column of Fastener
Installation Holes, OR (12) 16d 3--1/2” nails
(6 per side) in center column of Fastener
Installation Holes.

• For installation onto wood and into field
(not positioned over truss or support beam):
use (32) #12 2” screws (16 per side).

*see chart on pg. 3 for
maximum permitted
working angle
from perpendicular

NO

NO

OK

Ø

Ø

Содержание Temper Anchor Series

Страница 1: ...nd these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 7 Product Specific Applications 2 Limitations 2 3 Components and...

Страница 2: ...lude state regulations if applicable Consult regulatory agencies for more information on personal fall arrest systems and associated components Worker Classifications CAUTION Understand the following...

Страница 3: ...or 3 total Deceleration distance 4 total Height of harness dorsal D ring from worker s feet 6 total Required distance from anchorage 19 total Limitations Compatibility When making connections with Tem...

Страница 4: ...rking Angle From Perpendicular 6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6...

Страница 5: ...zed out from underneath fastener WARNING NEVER load anchor improperly Prior to installation refer to anchorage positioning chart pg 9 to ensure installation location will satisfy intended work applica...

Страница 6: ...s When not in use store equipment where it will not be affected by heat light excessive moisture chemicals or other degrading elements Prior to EACH use inspect Temper Anchor for deficiencies includin...

Страница 7: ...ticipate where workers will be performing their duties the routes they will take to reach their work and the potential and existing fall hazards they may be exposed to Fall protection equipment must b...

Страница 8: ...nnection per Temper Anchor IMMEDIATELY remove from use if exposed to forces of fall arrest WARNING 90040 Rev E May be used in multiple installation applications Always use new fasteners for each insta...

Отзывы: