14
Setting Auto-Closing Operation / Courtesy Light / Buzzer Responses
Auto-closing timer is turned off as default (the screw control is at fully “-”)
1. Optional Photo Eye* must be selected and properly connected and aligned to enable Auto
-Closing Operation. (* Contact your local operator supplier)
2. Turn the screw towards ‘+’ position to set to appropriate delay time (max. 2-1/2 minutes)
for the door to auto-close after fully opened.
Photo Eye must be selected and connected
3. When the delay time is reached within the door at fully open position, the operator beeps
twice and closes the door automatically.
1
2
3
x2
Courtesy Light / Beeper Responses
Operation / Condition
Courtesy Light / Beeper Responses
Operator is initially plugged-in (no travel limits stored)
Flash x 5
Reconnecting power (with travel limits stored)
Flash x 3
“RADIO SET” button is pressed
Beep x 1
Upon activation
Light On for 2.5 minutes
Upon activation by remote transmitters
Beep x 1, Light On for 2.5 minutes
Remote Transmitter / Keyless Entry PIN code accepted Beep x 2
Operator is triggered without programming
Beep x 5
Door travels with abnormal speed
Beep x 12 (1 beep / second)
Photo Eye System is obstructed during door-closing
Beep x 20 Medium Beep
The door is obstructed during travel
Beep x 25 Rapid Beep
Photo Eye Selection
Jumper off — Selected
Jumper on — Unselected
UP RADIO SET FORCE