background image

 

UP 

RADIO SET FORCE 

Setting DOWN Limit 

 

 

1. Press “LIMIT” button twice to enter DOWN-limit setting. “DOWN” LED is on. 

 

 

2. Press & hold the “DOWN” button, release the “DOWN” button when the door 

reaches the desired down limit position. 

 

 

3. During limit-setting mode, press “UP” or “DOWN” to fine-tune to desired down 

limit position. 

 

or 

4. When  the  door  is  at  the  desired  DOWN  limit  position,  press  “LIMIT”  button 

once,  “OK”  LED  flashes  twice  and  both  “UP”  and  “DOWN”  LEDs  are  on. 
DOWN limit is set and the operator is ready for Sensitivity Auto-Learning. 

 

 

10    

 

UP 

RADIO SET FORCE 

UP 

RADIO SET FORCE 

 

 

 

 

UP 

RADIO SET FORCE 

 

 

Содержание DCR2

Страница 1: ...DCR2 ROLLER DOOR OPERATOR Installation Instructions and Owner s Manual READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION Installer Permanently attach manual to the wall HSOMU03A 1...

Страница 2: ...t Saddle x1 set Anti Coning Clip x2 sets Operator Unit Remote Handset x2 Wireless Wall Button x1 Weight Bar mounting screw set x1 Manual Safety Label Optional Accessories Items and quantity may differ...

Страница 3: ...Travel Limits 4 5 turns of door drum approx Courtesy Light Light Source 6 x Ultra Bright LEDs Lighting Time 2 5 minutes Transmitter Frequency 433MHz Operation Range 50m open field Coding Type Fixed c...

Страница 4: ...oor Check that there is sufficient side clearance to fit the operator unit as below listed Door Type Minimum side clearance A Series 1 25mm deep tracks 90mm AA Series 2 50mm deep tracks 115mm All door...

Страница 5: ...sh the Emergency Release handle to disengage the motor drive ONLY when the drive is switched OFF and if possible when the door is fully closed Do not use the sensitivity adjustments to compensate for...

Страница 6: ...posite the end to which the operator is to be fitted is tightened securely This U bolt holds all the spring tension on the door once the other U bolt is released 5 Slide drive unit onto shaft as shown...

Страница 7: ...t Backup Bat Auto Close Timer function will only work when Photo Eye System is properly installed To activate Auto Close Operation Turn the knob towards for maximum delay time of 2 5 minutes To deacti...

Страница 8: ...n setting according to the illustrations below The corresponding LED is on upon key input View View 3 Press RADIO SET button to confirm setting The OK LED is on with 2 beeps x2 Caution Make sure the d...

Страница 9: ...hen the door reaches the desired up limit position 3 During limit setting mode press UP or DOWN to fine tune to desired UP limit position or 4 When the door is at the desired UP limit position press L...

Страница 10: ...desired down limit position 3 During limit setting mode press UP or DOWN to fine tune to desired down limit position or 4 When the door is at the desired DOWN limit position press LIMIT button once O...

Страница 11: ...e installa tion 1 Both UP and DOWN LEDs are on after limit setting press the FORCE button once to enter Sensitivity Auto Learning mode 2 The door will open and stop at UP limit for 2 seconds 3 Door wi...

Страница 12: ...g is completed 1 2 Enter Force Setting UP or 3 x2 To adjust DOWN Force Confirm 1 To adjust DOWN force press FORCE button once UP LED is on then press FORCE button again within 5 seconds DOWN LED is on...

Страница 13: ...r within a 30 seconds timeframe 2 Press any button on the transmitter within 30 seconds 3 OK LED flashes once and operator beeps twice acknowledging the transmitter is set x2 To DELETE ALL transmitter...

Страница 14: ...door automatically 1 2 3 x2 Courtesy Light Beeper Responses Operation Condition Courtesy Light Beeper Responses Operator is initially plugged in no travel limits stored Flash x 5 Reconnecting power wi...

Страница 15: ...tion for correct balance not binding Adjust if necessary Spray silicone lubricant into tracks Do not grease Check adjust safety sensitivity setting Check Limits BANGS HARD ON TRACK STOPS WHEN FULLY OP...

Страница 16: ...16 Parts Breakdown 2 1 3 8 9 10 4 11 5 12 6 7 19 6 15 13 21 18 14 16 20 23 17 22 24 25 27 26 28...

Страница 17: ...ransformer Mounting Plate 19 Drive Gear 6 Transformer Protection 20 Clutch Dock 7 Transformer 21 Clutch Release 8 U bolt 22 Finger Dog 9 Saddle 23 Clutch Retainer 10 Saddle Mounting Plate 24 Sungear D...

Страница 18: ...ase or 6 000 cycles whichever occurs first for the electronics and mechanics A cycle means one opening and closing cycle of the door 2 the remote controlled transmitters and accessories included with...