PX/QX/RX Version 4.20 User Manual – Issue B
- 23
-
User Menu
Lockout (PX Only)
Code-7
This option will only be available if at least one ACM is fitted to the system. If the lockout option is on
for a user then the user code will be ignored until the lockout is turned off.
User Menu
Expiry Date (PX Only)
Code-8
Expiry dates can be programmed for all users (panel and access users).
Expiry Date
Off
Expiry Date
Enter DDMMYYYY
3=Card
4=Authority
5=ACM Authority
6=Schedule
7=Lockout
8=Expiry Date
1=Name
2=PIN
7
Expiry Date
Thu 01 Jan 2004
0
1
0
1
2
0
0
4
To delete an expiry date, enter the day and month of 0000 and the current year. The user authority
and codes will be removed from the system at midnight on the expiry date.
Tel Number
Code-08
An authorised user can change any telephone number that has been programmed to use the speech
format, home beep or SMS formats. The available formats will depend on the system hardware
options. A telephone number of up to 16 digits can be programmed. This number can include pause
digits. Pause digits can be entered using the
Ð
button. This will be displayed as a “,” character. Each
pause digit represents a 1 second delay. Pauses may be required if you are signalling via a PABX or
if the call is routed through an old exchange.
Enter a single zero to turn off a telephone number. Press
to delete a single digit
.
Tel Number-1
01313332900
08=Tel Number
Tel Number
Number _
Not Available
No Authority
Tel Number-1
01313333802
the number is not used
for speech messages
0
1
8
enter the
telephone
An alarm in the home beep format is transmitted as a series of DTMF tones. For example if channel 3
was active the transmitted message would be:
3 3 3 < 2s delay> 3 3 3 < 2s delay > 3 3 3 < 2s delay> 3 3 3 < 2s delay >3 3 3
Where ‘3’ is the tone pair for DTMF digit 3. The channel information is repeated a maximum of 5 times
during a call.
Содержание PX500
Страница 1: ...PX QX RX Version 4 20 User Manual Issue B ...
Страница 45: ......