PX/QX/RX Version 4.20 User Manual – Issue B
- 24
-
Logs
The panel logs all events that occur in the system. All events stored in the event log are numbered in
the range 0-65535 (the event index). The event index will be reset to 0 when more than 65535 events
have been recorded. There are 2 logs, the security log and, if an ACM(s) is fitted, an access log. Each
log can be viewed in full or filtered form on a keypad and printed if a printer is connected to the
system. Options 16-18 will only be displayed if there is at least one ACM on the system. Only events
for authorised areas and access doors will be displayed or printed.
Circuit
Number-___
User
Number-____
Keypad
Number-__
Filter Date
Enter-DDMMYYYY
User
Number-____
Door
Number-__
1=Display
2=Print
12:00:00 Cct1
Bypassed
Fri 3 Jan 2003
00071
U2 Cct1
Bypassed
PIR in Hall
Bypassed
2
1
0
1
1
1
2
1
3
1
4
1
7
1
8
1
6
1
?
?
?
?
12=Log-User
13=Log-KP
14=Log-Date
15=Log-Alarm
16=A/Log Full
17=A/Log User
18=A/Log Door
10=Log-Full
11=Log-Cct
1
5
00001 Mon 07 Apr 2003 00:00:02 User 2 (Mr Smith) Logged On on KP 0
Event index Event date Event time
Event details
Use the button to change the
display view of an event and the
buttons to change the event being
displayed. When an event is printed all
the event data is printed.
?
Refer to the appendix C for details of all log messages.
Time
Code-20
Some users have the authority to change the time by up to 75 minutes from the time set by the
engineer if the user clock edit option is programmed. Time changes are recorded in the event log.
Time
Enter HH:MM
20=Time
Time
12:00
0
2
Out of Range
Time
13:00
1
3
0
0
Change greater
than 75 minutes