PX/QX/RX Version 4.20 User Manual – Issue B
- 27
-
Bypass
Code-30
The bypass option will only be available if a circuit(s) has been programmed as bypassable by the
installation engineer. The bypass circuit option allows the user to bypass a circuit that is in a fault
condition. When bypassed the alarm condition of a circuit is ignored. When a circuit is bypassed it is
ignored until the bypass is automatically removed when the circuit is next unset or until a user
removes the bypass. All bypass actions are stored in the event log. A bypass limit will have been
programmed by the installation engineer to limit the number of circuits that can be bypassed at any
one time. The system will display an error message if you try to exceed this limit.
30=Bypass
Circuit
Number ___
Enter circuit
number
Cct-01
Bypassed
1
0
Circuit
Limit 1 to max
?
Cct-01
Normal
Not Available
No Authority
Circuit was
not bypassed
Circuit was
bypassed
Circuit cannot
be bypassed
Cct-01
Normal
Not Available
At Bypass Limit
Max. Number of
circuits already
bypassed
3
0
Cct-01
Active
Circuit has a 24hr
response and is
already bypassed
Cct-01
Set
Circuit is in a set
area
Chime
Code-32
Certain circuit types can be selected as chime circuits when unset. To select the chime function for a
circuit, enter the circuit number. In the example chime is turned on for circuit 1.
32=Chime
Circuit
Number ___
Circuit-1
Front Door
1
0
3
2
Circuit-1
Chime-Off
Press any
button
Circuit-1
Chime-On
1