Keyswitch/Radio Keyfob Setting
As an alternative to setting and unsetting from a keypad, your system may be fitted with an optional
keyswitch, which permits setting and unsetting of a group by operating a keyswitch. The keyswitch
may be configured for any set mode. If your system is fitted with a radio interface then a radio Keyfob
may be programmed for setting.
Automatic Setting
The system may have been programmed by the installation engineer to automatically set all or parts
of the system according to a pre-programmed schedule. The schedule will have been programmed to
take into account the normal closing time, non-working days and holidays. The schedule may be
configured for any set mode.
Aborting The Setting Procedure
The setting procedure can be aborted at any time during the exit time by pressing
on the keypad
that was used to start setting, logging on to any other keypad, turning a keyswitch to the unset
position or an appropriate radio Keyfob.
Setting with Warnings
The system will automatically display any conditions that the user should be aware of before setting
the system. These conditions are described as set warnings and do not prohibit the user from setting
the system in the normal way.
Workshop
Seconds Left-005
1=Workshop
2=Office
1
Loading Door
Isolated
=Set
The set warnings include:
1. Bypassed circuit(s)
2. Circuit(s) on soak test has failed (a special circuit test mode set up
by the installation engineer)
3. Isolated circuit(s)
4. Line Fault (only when setting with telephone line fault is allowed)
5. Shunted circuit(s)
6. Battery test faults, when setting is allowed with this type of fault.
7. 230v mains faults, when setting is allowed with this type of fault.
Easy Set
If easy set mode 1 is programmed then the system will start to part set when you log on. During the
part set exit time, if the exit door circuit is opened and closed, the system will full set. Pressing the
key during the setting time will cancel setting. If easy set mode 2 is programmed then the system
can be set without logging on to a keypad. Up to 8 parts can be set in this way (depends on the
control panel type). For example to set part 1 of your system from 1 +
.
The system can be set by
entering 0 +
.
If using a mini keypad then the house symbol buttons can be used to set.
+
= set first group or area.
+
= set second group or area.
and
+
= set first and second group or area.