Page 37
Issue 07/2011
Installation of generator
Installation of generators of model 132
Assembly example 2: R+W drive shaft with cone hub connection
Assembly
>
Slide the metal bellows couplings onto the
shafts to be joined.
>
If the axial position is correct, tighten the
mounting screws
[2]
with a torque key
crossways in three turns,
- first with 1/3 of the torque,
- then with 2/3 and
- finally, to the full specified torque.
Specified moment
ð
Manufacturer's description, drive shaft
manufacturer
The clamping procedure is now complete.
Important
►
Do not tighten the mounting screws any further. Doing so
could damage the cone hub connection!
Mount the intermediate tube according to the descriptions for the clamping
nub connection.
Disassembly
>
Unscrew the flange mounting screws
[1]
.
>
Press the metal bellows together.
>
Remove the intermediate tube.
Support the intermediate tube where necessary!
>
Undo the mounting screws
[2]
evenly.
>
Drive out the cone hub with the three set screws
[3]
.
>
Slacken the set screws immediately.
1
2
3