18
GPX-SL25 Instruction Manual
rev 03.21.13
INPUT CONNECTIONS
FIRST OPERA
TOR
A
CCESSORY
RED
BLK
ORG
BLU
GRN
CLS EDG
OPN EDG
BLU
ORG
WHT
GRN
5
3
2
1
4
All inputs are dry-contact, normally open.
CLS EDGE:
(Typically for use with loop detector device)
• Activation of this input while the gate is closing will cause
the gate to stop and reverse direction for approximately 2
seconds.
• Activation of this input while gate is opening has no
effect (gate will continue to open).
Autoclose will reset.
• Activation of this input while gate is idle will prevent gate
from closing.
OPN EDGE:
(Typically for use with loop detector device)
• Activation of this input while the gate is opening
will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while gate is closing has no effect
(gate will continue to close).
• Activation of this input while gate is idle will prevent gate
from opening.
ORG
:
(Typically used with photo beam devices, loop
detectors or other non-contact sensors)
• Activation of this input while the gate is closing will cause
the gate to stop and return to the open position
• Activation of this input while gate is opening has no
effect (gate will continue to open).
Autoclose will reset.
• Activation of this input while gate is idle will prevent gate
from closing.
BLU:
(Typically for use with exit loop or wand)
• Activation of this input will open the gate if it’s not
already at the open position.
• Activation of this input while gate is at the open limit will
restart the auto close time (if enabled).
WHT:
(Typically used with doorbell button or hard wired
key pad)
• Each activation at this input will cycle the operation as
follows
... X Open X STOP X CLOSE X STOP X OPEN X ...
1
2
3
4
5