ON OFF
Low Voltage Wire
from Transformer
or Solar Panel
Gate Opener
Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).
120 Volt indoor
Transformer
(surge protector
not supplied)
PVC conduit (not included)
to protect wire from lawn
mowers and weed eaters.
Control and Battery Box
Step 3
Lay the low voltage wire in a trench
following a path from the selected electrical
outlet to the control box. Wires coming up
from the ground should be run through PVC
conduit to protect them from accidental
damage. Be sure to bury the wire laid in the
trench.
VAR5
VAR6
K1
PF1
K2
BATT
+
BATT
–
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX OFF
JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
G
TO Inc.
Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR
.
FIRST OPR
.
RED
BLK
14 VAC
OR
SOLAR
ON OFF
Low Voltage Wire from
Transformer or Solar
Step 4
Bring enough wire up through the PVC conduit to reach the
control board.
Step 5
Strip 3/16” off the ends of the low voltage wire and twist
tightly. Attach these ends to the 14VAC OR SOLAR terminals
located on the terminal block. Be certain not to let the
exposed wires touch each other!
Insert one transformer wire into a 14VAC OR SOLAR
terminal. Insert the other transformer wire into the remaining
14VAC OR SOLAR terminal. The transformer wires can be
connected to the 14VAC OR SOLAR terminals regardless of
color/polarity.
Tighten set screws against exposed end of wires.
Step 6
At the AC outlet, strip 1/2” of insulation from the ends of
the low voltage wire. Attach these stripped ends to the
transformer terminals.
Make sure the exposed wires
do not touch each other!