Technical Specifications
GTO/ACCESS SYSTEMS 2000XLS AUTOMATIC GATE OPERATOR
DRIVE
• Low friction screw drive (linear actuator) rated for -5˚F to +160˚F (-21˚C to +71˚C). Use of GTO battery heater
FM316 (Not solar compatible) is recommended in extreme cold temperatures
• Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 395 rpm.
• Maximum opening arc of 110˚. Approximate opening time (90˚): 15-19 seconds, depending on weight of gate.
POWER
• The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 120 Vac, 14 Vac output transformer.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher
ampere rated fuses; doing so will void your warranty and may damage your control board.
• One (1) blade style fuse is rated for 15 A.
• For optional solar charging see page 2.
CONTROL
• GTO microprocessor-based control board is set for pull-to-open gate installations. Jumper can be removed to
accommodate an optional kit for push-to-open gates (see Accessory Catalog).
• A circuit on the control board regulates charging. “Sleep draw” is 15 mA; “active draw” is 2 to 5 A.
• Auto-memorization of digital transmitter code.
• GTO built in RF receiver tuned to 318 MHz.
• Operator length with push-pull tube fully retracted is 33
3
/
4
”, mounting point to mounting point, arm stroke 15”
max.
• Minimum gate length is 5 ft.
• Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.
• Power terminal block accommodates a transformer or solar panels (not both).
• Accessory terminal block fully compatible with GTO push button controls, digital keypads, loops detectors, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
• Direct drive for automatic gate lock.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/ACCESS 2000XLS
Automatic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the
type and condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the
specifications listed on page 2.
* An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
Gate Weight
Gate Length
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
16 ft.
14 ft.
12 ft.
5 to10 ft.
135
145
155
165
50 lb.
120
130
140
150
100 lb.
105
115
125
135
150 lb.
N/R
100
110
120
200 lb.
N/R
80
90
100
300 lb.
N/R
N/R
70
80
400 lb.
N/R
N/R
N/R
60
500 lb.
N/R - Not Recommended
PRO-SW2000XLS Gate Capacity Chart