SIMPLIFIED INSTRUCTIONS FOR K800 24V WITH KS 24V
The motor is set to open towards the right.
If it opens to the left, the LSO and LSC wires of the J11 terminal
and the motor wires on the J12 connector must be inverted.
2° Connecting the accessories
3° Installing and adjusting the limit plate cams
Position the cams on the rack.
Tighten the two screws to lock them. How to finely
adjust cam intervention is explained below.
Release the motor (turn the key counter clockwise until the
limit is reached without forcing) and move the gate by hand
Check when the cams are activated.
Note: The cams must press the electric microswitches
before the mobile part touches the mechanical stops.
IMPORTANT
POWER SUPPLY
230V 50-60Hz
TRANSFORMER
BLUE
C
C
NO
NO
NC
NC
A+A- Observe the polarity of the
photocells’ electrical supply
1
2 3
4
5
ANTENNA - Use an RG58
co-axial cable
A* A S
C NC
A* A S
POWER SUPPLY
230V 50-60Hz
TRANSFORMER
BLUE
C
C
NO
NO
NC
NC
A+A- Observe the polarity of the
photocells’ electrical supply
1
2 3
4
5
ANTENNA - Use an RG58
co-axial cable
A* A S
C NC
A* A S
1° Connecting the motor and limit switch
(done in the factory)