background image

SIMPLIFIED INSTRUCTIONS FOR K800 24V WITH KS 24V

The motor is set to open towards the right.

If it opens to the left, the LSO and LSC wires of the J11 terminal 
and the motor wires on the J12 connector must be inverted.

2° Connecting the accessories

3° Installing and adjusting the limit plate cams

Position the cams on the rack.
Tighten the two screws to lock them. How to finely 
adjust cam intervention is explained below.

Release the motor (turn the key counter clockwise until the 
limit is reached without forcing) and move the gate by hand
Check when the cams are activated. 
Note:  The cams must press the electric microswitches 

before the mobile part touches the mechanical stops.

IMPORTANT

POWER SUPPLY

230V 50-60Hz

TRANSFORMER

BLUE

C

C

NO

NO

NC

NC

A+A-  Observe the polarity of the 

photocells’ electrical supply

1

2 3

4

5

ANTENNA - Use an RG58 

co-axial cable

A* A S

C NC

A* A S

POWER SUPPLY

230V 50-60Hz

TRANSFORMER

BLUE

C

C

NO

NO

NC

NC

A+A-  Observe the polarity of the 

photocells’ electrical supply

1

2 3

4

5

ANTENNA - Use an RG58 

co-axial cable

A* A S

C NC

A* A S

1°  Connecting the motor and limit switch 
(done in the factory)

Отзывы: