FST 75/150
260-2210-002 EN064
Page 19 / 37
Configure traffic light functions for K5-K8
The FST 75/150 offers some function sets for the control of traffic lights. By choosing one of them, the
Relays K5-K8 are automatically configured to the desired function.
For manually configuration please refer to chapter „Free configuration of relays K5-K8”.
6.1
Traffic control mode
Save
w
0
No function
1
One-way traffic without regulation of right of way
2
Right of way without preference
Press rotary switch
3
Right of way with preference from inside
4
Right of way with preference from outside
6.2
Extension of green phase time
Save
w
0..90 Setting of Extension time in sec
Press rotary switch
6.3
Time of prewarning
Save
w
0..10 Setting of prewarning time in sec
Press rotary switch
6.4
Doorway evacuation time
Save
w
0..90 Setting of doorway evacuation time in sec
Press rotary switch
6.5
Red traffic light in closed position
Save
w
0
Red traffic light off
1
Red traffic light inside on
2
Red traffic light outside on
Press rotary switch
3
Red traffic light inside an outside on