DESCRIPTIOn OF THE COMPOnEnTS
14
CoboSafe-Scan
325-2810-013US13
■
The correct evaluation of the pressure measurement is only possible if the correct tem-
perature and humidity parameters are specified. The values must be determined with a
suitable hygrometer at the point of measurement.
■
The correct specification of the type used is required for the evaluation. An incorrect type
specification will produce incorrect measured values!
GEFAHR
WARNING
Risk of injury due to incorrect handling of the pressure
measuring film
■
Risk of injury due to color change!
■
Protect pressure measuring films from UV radiation.
■
Do not touch the matte side of the film.
■
Ensure specified application and storage conditions for
pressure measuring film.
■
An incorrect type specification during import into CoboSa-
fe-Vision software will generate incorrect measured values!
The exposure to sunlight, skin contact and ageing can
falsify the measurement results of the pressure film. This
can erroneously classify robots as safe. Severe injuries to
collaborating personnel may result.
6.1.2 Durability
Fujifilm Prescale films have a limited shelf life. The expiry date is shown on the label [1].
6.1.3 Storage
■
note the expiration date. Dispose of expired goods properly.
■
After use, repack the rolls in the UV-resistant original sleeves and place the rolls back
in the original carton with the correct labeling to ensure safe identification and a clear
overview of the shelf life.
■
Protect the packaging unit from moisture.
Fig. 5: label - expiry date