- 6 -
PTIM 1000
ASI interfaces
Standard: .....................................................................DIN EN 50083-9
Format: ..............................................................MPEG ISO IEC 13818-1
User data rate: .................................................................2 … 90 Mbit/s
Impedance: .................................................................................... 75
Ω
Level (input / output): .....................................................800 mV
pp
± 10%
Return loss (input):...............................................> 17 dB (5 … 270 MHz)
Connections
RF inputs: ............................................................................2 IEC sockets
RF loop-through outputs: .......................................................2 IEC sockets
RF output: ..........................................................1 IEC socket (no function)
LAN: ................................................................................ 1 RJ 45 socket
ASI input: .......................................................................... 1 BNC socket
ASI output: ......................................................................... 1 BNC socket
Connection strip (10-pin): ..................for supply voltages and control circuits
RS 232 socket: ..................................... serial interface for software update
Common Interface: ....................... 1 (several services can be descrambled).
Remote maintenance
Remotely controllable (via PSW 1000*): ..............................................yes
(* and a corresponding management unit)
Содержание PTIM 1000