8. 2.66" Commercial Tank Stiffener Instructions (Outside Stiffened)
34
PNEG-1859
2.66" Corrugation 135' Diameter Tank with 50 PSF Snow Roof
2.66'' Corrugation Commercial Stiffeners Splice Details
When installing bottom stiffeners, you may find that in some cases the stiffener with base plate attached
will not rest on the foundation (due to unlevel foundation, etc.). Shim plates have been furnished and
should be used to fill opening between base plate and concrete.
IMPORTANT:
If shim plates are not used where required, the downward pressure of the stiffeners will not
be transferred directly to the foundation and bin failure could result.
Stiffener Color Code Chart
NOTE:
Some colors are different than those used for sidewall sheets
.
*NOTE:
Only Orange on 1 ring stiffener
.
Figure 8C
Stiffener Gauge
Color Code
Stiffener Gauge
Color Code
15
Red/Orange*
6
White
14
Green/Orange*
5
Fluorescent Green
13
Dark Blue
5+12
Gold/Black
12
Black
5+10
Gold/Light Blue
11
Pink
5+8
Gold/Yellow
10
Light Blue
5+5
Gold/Fluorescent Green
9
Purple
5E+5U
Ochre/Gold/White
8
Yellow
5E+5E
Ochre/Gold/White/Brown