background image

14

INSTALLATION

1. Adjust hanger extensions to fit

roof opening and install the

power spread unit.

2. Use the 9/32" hole at the end of

each hanger extension and bolt

hanger extensions to hatch

collar.

3. Then tighten all bolts holding

hanger extensions.

4. Once unit is installed, use a

carpenter's level across the top

of the spreader cone to make

sure it is level in all directions

(Figure 5).

5. If required, add spacer washers

between hanger brackets and

hanger extensions to level unit

(Figure 6).

Figure 5: Mount spreader and check with level.

Mount unit level inside the bin

Carpenter's level

Grain spreader

Use washers
to level unit
(if required)

Hanger extension

(SPD-2149)

Hanger extension

(SPD-2008)

Figure 6: Use washers to level unit.

The 1HP motor is protected with an

internal automatic reset overload.

Before servicing, all power to the unit

must be disconnected and locked out

to avoid a possible reset/restart and

serious injury.

Before connecting and applying

power, rotate the spreader blade by

hand to be certain it rotates freely

without obstruction. The motor turns

the spreader blade counterclockwise

as viewed from above the unit. The

super spread unit requires 115

or 230 volt 1 PH  or 230 or 460 volt

3 phase power supply. The mini-

mum wire size is 14 gauge for runs

up to 200 feet. It is advisable to pro-

vide additional protection such as

15 amp slow blow fuses or 20 amp

circuit breaker. Consult a licensed

electrician for wire size on longer

runs. Regardless of grain type and

bin size, the grain flow must be di-

rectly down (vertical) and centered

(horizontal) within the spreader cone

(Figure 7). This has to be done to

prevent high and low grain surface

areas from one side of the bin to the

other.

Spreader cone

(SPD-2007)

Grain flow

Figure 7: Grain flow must be

centered within the spreader cone.

Содержание FFD-200-1

Страница 1: ...1 Scattergrain Grain Spreader Installation Operating Instructions Owner s Manual MANUAL PNEG 267 MODEL FFD 200 1 MODEL FFD 200 3 PNEG 267...

Страница 2: ...2...

Страница 3: ...ware List For FFD 200 1 FFD 200 3 8 Super Spread Parts List 10 Super Spread Parts Assembly 11 Super Spread Installation 12 Single Phase Dual Voltage Wiring Diagram 13 Three Phase Dual Voltage Wiring D...

Страница 4: ...MODIFICATIONS TO THE PRODUCT NOT SPECIFICALLY COVERED BY THE CONTENTS OF THIS MANUAL WILL NULLIFY ANY PRODUCT WAR RANTY THAT MIGHT HAVE BEEN OTHERWISE AVAILABLE THE FOREGOING WARRANTY SHALL NOT COVER...

Страница 5: ...ous injury or death SAFETY GUIDELINES DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury This is the safety alert symbol It is used to alert...

Страница 6: ...al concern of the GSI Group Inc GSI is your safety and the safety of others associated with grain handling equipment This manual is written to help you under stand safe operating procedures and some o...

Страница 7: ...is supplied to your unit Safety decals should be read and understood by all people in the grain handling area The bottom right de cal should be present on the inside bin door cover of the two ring do...

Страница 8: ...Bracket 5 16 18 x 1 1 4 N F T Bolt grade 5 5 16 Lockwasher 5 16 18 Hex Nut 5 16 Flatwasher 5 16 18 x 1 4 Set screw 1 4 x 1 Roll Pin 3 8 Eyebolt Danger Decal 1 4 Set Screw 1 4 x 1 Roll Pin 1 4 Set Scre...

Страница 9: ...ets All GSI bins with stan dard peak roof cap have a hatch collar diameter 31 1 2 Loosely mount each hanger extension to a hanger bracket using the ap propriate slots with two 5 16 18 x 1 1 4 bolts tw...

Страница 10: ...special 1 HP 3 Phase C Face Motor special Pinion Gear MI Gear Box With 56C Adapter 069 1304 0 3 4 Seal Tite Elbow CSA 3 4 Seal Tite CSA Approved 3 4 45 DEG Seal Tite Fitting Capacitor Box Capacitor B...

Страница 11: ...SEMBLY WARNING Automatic Reset Overload Protection NOTE Tighten set screws against flat on motor shaft Special Gearbox Lubricant Locating holes must be aligned for proper operation Not required for sm...

Страница 12: ...kwise as viewed from above the unit If the three phase unit turns clockwise the rotation can be changed This may be done by interchanging any two of the three power wire con nections The rotation cann...

Страница 13: ...and the extra wire on the capacitor go to L1 4 goes to L2 and 2 and J tie together E from the motor goes to E on the capacitor O from the motor goes to O on the capacitor For 230 volts 1 goes to L1 2...

Страница 14: ...efore servicing all power to the unit must be disconnected and locked out to avoid a possible reset restart and serious injury Before connecting and applying power rotate the spreader blade by hand to...

Страница 15: ...er and fill rate Figure 8 2 Spreader diverters are used to increase or decrease grain flow resistance over spreader blade With the diverters straight Fig ure 9 the grain will travel fur ther Angled gr...

Страница 16: ...lts and pivot dampers to nearly closed position SMALL BIN 24 DIA AND LESS OPERATION PROCEDURE Increase loosen U bolts and pivot the blade single diverter side upward Increase center filling loosen bol...

Страница 17: ...ration If problem con tinues check power supply for volt age and check blade of unit for free dom of rotation If motor pinion requires removal for any reason it must be properly installed and located...

Страница 18: ...reader never allow grain to flow into spreader at an angle or off center Trouble Large doughnut shaped ring caused by grain hitting high on bin wall Grain is high in center of bin small doughnut Grain...

Страница 19: ...19...

Страница 20: ...20 1004 E Illinois St Assumption IL 62510 Phone 217 226 4421 Toll Free Fax 888 741 3004 Rev June 26 2003 G R A I N C O N D I T I O N I N G S Y S T E M S...

Отзывы: