English
49
Dynamic Marking:
choose to show or don’t show the track
Type
:
There are three types. Motion, person, Vehicle.
Alarm Number:
Count the number of alarms, set the value from 1-255
Start Time:
Set alarm start time
End Time:
Set alarm end time
Rule Number
:
Draw a rule area on the area map, the rule switch and rule type of each rule
are independent, and they need to be opened, closed or set separately.
Rule Switch
:
The switch of each rule.
Rule Type
:
Setup to each rule, A->B means can detect A to B direction moving, B->A means can
detect B to A direction moving.
8.7.1.7 HM – Heat Map
The Heat Map (HM) statistics function uses a logic similar to motion to judge whether there is a
change in transmission in each area of the monitoring area, and save and upload the change at
10 minutes intervals. Through a large number of statistics, user can view the change in each area
in the scene. This function only supports data logging, not alarm.
Figure 8.23
Enable
:
Enable or disable HM
Rule Number
:
Only one rule is allowed to be turned on. The entire screen has been checked
in the default area. If you need to customize the area, check the box in the upper left corner
of the screen, and drag the points placed at the four corners of the screen to re-divide the