English
48
Sensitive
:
The sensitivity of triggering SOD can be set as 1-4. The larger the value is, the more
sensitive the SOD alarm is. The default sensitivity of SOD is set as 3
Dynamic Marking:
choose to show or don’t show the track
Rule Number
:
Max set 4 rule number. Draw a rule area on the area map, and click to the next
few rules, then you can draw rules on the area map. The rule switch and rule type of each rule
are independent, and they need to be opened, closed or set separately.
Rule Switch
:
The switch of each rule
Rule Type
:
Setup to each rule, Lost means can detect something is missing, Legacy means can
detect things left there, Lost & Legacy means can detect above two.
8.7.1.6 CC – Cross Counting
Camera can record the specific objects crossing line in monitoring area by Cross Counting (CC)
function. Set the crossing line, there are two areas (A and B) on two sides of line. When the rule
is A→B. it means object crosses the line from area A to area B. The count in increases by one.
When the object enters from area B and cross the line to area A, the count out increases by one.
The alarm will only be triggered when the count in minus the count out is greater than or equal
to the set Alarm Number count. The interface is as shown in the figure below.
Figure 8.22
Enable
:
Enable or disable CC
Sensitive
:
The sensitivity of triggering Cross Counting can be set as 1-4. The larger the value
is, the more sensitive CC alarm is. The default sensitivity of perimeter intrusion detection is
set as 2.